(d) The application of paragraph (c) of this section may be illustrated by the following examples: Example (1): A developer plans to construct a 100 unit condominium apartment building...
Search Results "9-1-1 Service"
Commonly Searched Documents
-
§100.205(d)
-
Calculation of Percentages
wheelchair accessible water closets (16” – 18” centerline from side walls or partitions), specifying to the midpoint of the range (17”) will accommodate any construction variations up to 1”...
-
[ADA Title III] Readily achievable
In determining whether an action is readily achievable factors to be considered include -- (1) The nature and cost of the action needed under this part; (2) The overall financial...
-
10 - foot straightedge method
When used as a specification or requirement, a maximum deviation in length under the straightedge is given, such as "no point shall exceed 1/4 inch under a 10 - foot straightedge."...
-
JURISDICTION
. § 12131(1). The Department is authorized under 28 C.F.R....
-
§ 38.23(b)(13) Handrails
handrail shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than 1/...
-
§ 38.95(b)(13) Handrails
handrail shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than 1/...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Where a door is provided the symbol shall be mounted within 1 inch (25 mm) of the vertical centerline of the door....
-
§ 38.125(b)(13) Handrails
handrail shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than 1/...
-
§ 38.83(b)(13) Handrails
Handrails shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than 1/...
-
11B-404.2.3 Clear width
Exceptions: 1. In alterations, a projection of 5/8 inch (15.9 mm) maximum into the required clear width shall be permitted for the latch side stop. 2....
-
11B-233.3.1.2.6.4 Test number three, unusual characteristics test
An accessible route to a building entrance is impractical due to unusual characteristics of the site when: 1....
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
[ADA Title III §36.104] Readily achievable
In determining whether an action is readily achievable factors to be considered include -- 1) The nature and cost of the action needed under this part; 2) The overall financial resources...
-
11B-207.1 General
International Building Code (2000 edition and 2001 Supplement) or section 1007 of the International Building Code (2003 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1)...
-
12181(7)(F)
(F) a laundromat, dry-cleaner, bank, barber shop, beauty shop, travel service, shoe repair service, funeral parlor, gas station, office of an accountant or lawyer, pharmacy, insurance office...
-
Fixed Route System and Demand Responsive System
In making this determination, one of the key factors to be considered is whether the individual, in order to use the service, must request the service, typically by making a call....
-
TTYs: ADA Standard Section 704.4
Ensure that sufficient electrical service is available where TTYs are to be installed....