At least one wheelchair space complying with 11B-802.1 shall be provided in team or player seating areas serving areas of sport activity....
Search Results "Wheelchair Space"
Commonly Searched Documents
-
11B-221.2.1.4 Team or player seating
-
11B-221.2.1.4 Team or player seating
At least one wheelchair space complying with 11B-802.1 shall be provided in team or player seating areas serving areas of sport activity. ...
-
11B-221.2.1.4 Team or player seating
At least one wheelchair space complying with 11B-802.1 shall be provided in team or player seating areas serving areas of sport activity....
-
3. Exception to Ramp Running Slope
The MDE NPRM proposed that where there is a change in level at the entry of a wheelchair space that is greater than 1½ inches, the entry shall be ramped and have a running slope not steeper...
-
221.2.1.4 Team or Player Seating
At least one wheelchair space complying with 802.1 shall be provided in team or player seating areas serving areas of sport activity....
-
Changes in Level at Entry to Wheelchair Spaces (M303.3)
M303.3 includes technical criteria for changes in level at the entry to a wheelchair space as may occur at wheelchair weight scales with raised platforms....
-
4.2.3* Wheelchair Turning Space
The space required for a wheelchair to make a 180-degree turn is a clear space of 60 in (1525 mm) diameter (see Fig. 3(a)) or a T-shaped space (see Fig. 3(b))....
-
4.2.3* WHEELCHAIR TURNING SPACE
The space required for a wheelchair to make a 180-degree turn is a clear space of 60 in (1525 mm) diameter (see Fig. 3(a)) or a T-shaped space (see Fig. 3(b))....
-
ELECTRIC VEHICLE CHARGING SPACE (EV Space)
A space intended for charging electric vehicles....
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
12207(c)(2) "Wheelchair" defined
(2) "Wheelchair" defined For purposes of paragraph (1), the term "wheelchair" means a device designed solely for use by a mobility-impaired person for locomotion, that is suitable for...
-
5.9.2.1 Standing Supports on Single Ramped Entry Raised Platforms with Wheelchair Spaces Recommendations
5.9.2.1 Standing Supports on Single Ramped Entry Raised Platforms with Wheelchair Spaces Recommendations The Committee recommends standing supports located on both sides of platforms,...
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: A running slope not steeper than 1:8 shall be permitted for ramp runs with a maximum height of 2 ½ inches...
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side with a drop off.
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on both sides.
-
5.8.1.1 Clear Platform Size
5.8.1.1 Clear Platform Size. The platform should be a minimum clear width of 32-inches and a minimum clear length of 40-inches.
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on each side.
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12.
-
11B-305 Clear floor or ground space
[See subsections ...]
-
5.9.2.2 Standing Supports on Dual Ramped Entry Raised Platforms with Wheelchair Spaces Recommendations
5.9.2.2 Standing Supports on Dual Ramped Entry Raised Platforms with Wheelchair Spaces Recommendations The Committee recommends standing supports located on one side of the platform,...
-
Maneuvering Clearance: ADA Standard Section 305.7
Section 305.7 covers the current ADA Standards for additional maneuvering clearance needed when the clear floor or ground space is located in an alcove.
-
5.8.1.2.1 Ramped Entry Slope Recommendations
Industry experts spoke to the concern for facility space often expressed by healthcare entities....