Where boarding piers are provided at boat launch ramps, at least 5 percent, but no fewer than one, of the boarding piers shall comply with Section 11B-1003.3.2....
Search Results "Vehicle Ramp"
-
11B-235.3 Boarding piers at boat launch ramps
-
11B-812.5.1 Accessible route to building or facility
EVCS complying with Section 11B-812 that serve a particular building or facility shall be located on an accessible route to an entrance complying with Section 11B-206.4. Where EVCS...
-
11B-812.5.1 Accessible route to building or facility
EVCS complying with Section 11B-812 that serve a particular building or facility shall be located on an accessible route to an entrance complying with Section 11B-206.4. Where EVCS...
-
11B-228.3.1.1 Existing facilities
Where new EVCS are added to a facility with existing EVCS, the requirements of Section 11B-812 shall apply only to the new EVCS installed. Alterations to existing EVCS shall comply...
-
11B-228.3.1.1 Existing facilities
Where new EVCS are added to a facility with existing EVCS, the requirements of Section 11B-812 shall apply only to the new EVCS installed. Alterations to existing EVCS shall comply...
-
11B-406.5.2 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 48 inches (1219 mm) minimum....
-
11B-406.5.2 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 48 inches (1219 mm) minimum....
-
4.8.5* Handrails
If a ramp run has a rise greater than 6 in (150 mm) or a horizontal projection greater than 72 in (1830 mm), then it shall have handrails on both sides....
-
If the manufacturer states that the design load is 800 pounds, can the transportation operator limit actual use to 600 pounds for safety reasons?
The National Highway Traffic Safety Administration’s (NHTSA) motor vehicle safety regulations require that a wheelchair lift be tested to withstand a 600-pound load....
- Figure 503.3 Passenger Loading Zone Access Aisle – Drawing from the U.S. Access Board
-
106.5.13 Boat Launch Ramp
A sloped surface designed for launching and retrieving trailered boats and other water craft to and from a body of water.
-
11B-505.10.1 Top and bottom extension at ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
11B-505.10.1 Top and bottom extension at ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
405.4 Floor or Ground Surfaces
Floor or ground surfaces of ramp runs shall comply with 302. Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
405.4 Floor or Ground Surfaces
Floor or ground surfaces of ramp runs shall comply with 302. Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
11B-505.1 General
Handrails provided along walking surfaces complying with Section 11B-403, required at ramps complying with Section 11B-405, and required at stairs complying with Section 11B-504 shall comply...
-
11B-505.1 General
Handrails provided along walking surfaces complying with Section 11B-403, required at ramps complying with Section 11B-405, and required at stairs complying with Section 11B-504 shall comply...
-
§35.151(e)
(e) Curb ramps....
-
§ 38.29(e)
(e) For vehicles in excess of 22 feet in length with front-door lifts or ramps, vertical stanchions immediately behind the driver shall either terminate at the lower edge of the aisle-facing...
-
11B-812.7.3 Lettering
The words “NO PARKING” shall be painted on the surface within each access aisle in letters a minimum of 12 inches (305 mm) in height and located to be visible from the adjacent...
-
11B-812.10.1 General
EV chargers shall comply with Section 11B-812.10.
-
11B-812.7.3 Lettering
The words “NO PARKING” shall be painted on the surface within each access aisle in letters a minimum of 12 inches (305 mm) in height and located to be visible from the adjacent...
-
11B-812.10.1 General
EV chargers shall comply with Section 11B-812.10.
-
405.1 General
Ramps on accessible routes shall comply with 405....