The International Symbol of TTY shall comply with Figure 11B-703.7.2.2.
Search Results "Stair Signage"
-
11B-703.7.2.2 International Symbol of TTY
-
11B-810.6.3 Station names
Stations covered by this section shall have identification signs complying with Section 11B-703.5. Signs shall be clearly visible and within the sight lines of standing and sitting...
-
11B-703.8.9 Height above floor
Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character. Heights of low resolution...
-
11B-703.2 Raised characters
Raised characters shall comply with Section 11B-703.2 and shall be duplicated in Braille complying with Section 11B-703.3. Raised characters shall be installed in accordance with...
-
11B-703.6.3 Text descriptors
Pictograms shall have text descriptors located directly below the pictogram field. Text descriptors shall comply with Sections 11B-703.2, 11B-703.3 and 11B-703.4.
-
11B-703.2.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”. [2010...
-
11B-703.7.2.2 International Symbol of TTY
The International Symbol of TTY shall comply with Figure 11B-703.7.2.2.
-
11B-810.6.3 Station names
Stations covered by this section shall have identification signs complying with Section 11B-703.5. Signs shall be clearly visible and within the sight lines of standing and sitting...
-
11B-703.8.9 Height above floor
Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character. Heights of low resolution...
-
11B-703.2 Raised characters
Raised characters shall comply with Section 11B-703.2 and shall be duplicated in Braille complying with Section 11B-703.3. Raised characters shall be installed in accordance with...
-
11B-703.6.3 Text descriptors
Pictograms shall have text descriptors located directly below the pictogram field. Text descriptors shall comply with Sections 11B-703.2, 11B-703.3 and 11B-703.4.
-
11B-216.8.3 Signs at toilet and urinal compartments
Where both toilet compartments and urinal compartments are provided, each individual compartment shall be identified with a sign complying with Sections 11B-703.1 through 11B-703.5....
-
11B-703.7.2.3 Volume control telephones
Telephones with a volume control shall be identified by a pictogram of a telephone handset with radiating sound waves on a square field such as shown in Figure 11B-703.7.2.3.
-
11B-703.2.2 Case
Characters shall be uppercase.
-
505.2 Where Required
Handrails shall be provided on both sides of stairs and ramps....
-
505.2 Where Required
Handrails shall be provided on both sides of stairs and ramps....
-
505.2 Where Required
Handrails shall be provided on both sides of stairs and ramps....
-
11B-504.3 Open risers
Open risers are not permitted. Exceptions: 1. On exterior stairways, an opening of not more than ½ inch (12.7 mm) may be permitted between the base of the riser and the...
-
11B-504.3 Open risers
Open risers are not permitted. Exceptions: 1. On exterior stairways, an opening of not more than ½ inch (12.7 mm) may be permitted between the base of the riser and the...
-
11B-504.3 Open risers
Open risers are not permitted. Exceptions: On exterior stairways, an opening of not more than ½ inch (12.7 mm) may be permitted between the base of the riser and the...
-
505.2 Where Required
Handrails shall be provided on both sides of stairs and ramps....
-
F216.9.1 Identification Signs
Public TTYs shall be identified by the International Symbol of TTY complying with 703.7.2.2.
-
216.9.1 Identification Signs
216.9.1 Identification Signs. Public TTYs shall be identified by the International Symbol of TTY complying with 703.7.2.2.
-
11B-216.9.1 Identification signs
Public TTYs shall be identified by the International Symbol of TTY complying with Section 11B-703.7.2.2.