Rationale for final recommendation Having an accessible transfer surface height is critical to facilitate independent patient transfers to equipment used by patients both in a supine,...
Search Results "Patient Lift"
-
5.1.4 Transfer Surface Height Measurement for M301 and M302
-
Are stairway chairlifts permitted?
No, stairway chairlifts cannot be used where platform lifts are permitted by the ADA Standards (§206.7) although they are addressed by the ASME A18.1 Standard....
-
M301.3.1 Transfer Supports (Section-by-Section Analysis)
The MDE NPRM proposed to require transfer supports to be provided for use with transfer sides on diagnostic equipment used by patients in the supine, prone, or side-lying position, and that...
-
M301.3.3 Head and Back Support (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed to place the requirements for head and back support for diagnostic equipment used by patients in the supine, prone, or side-lying position in M301...
-
6c.
Is there at least a 30-inch by 48-inch clear floor space on the wheelchair lift? Yes _____ No _____...
-
5.9.1 Standing Supports Recommendation In Reference To Mammography Equipment
During discussion, there was general agreement that the real use of these supports is for positioning, and thus, not meant to support the full weight of the patient or to keep a patient...
-
Aquatic Recreation Facilities
The accessible means of entry can be either a pool lift, sloped entry, or transfer system....
-
§ 38.95(b)(11) Boarding direction
The lift shall permit both inboard and outboard facing of wheelchairs and mobility aids....
-
Transfer Supports Location and Configuration M301.3 and M302.3
Transfer Supports Location and Configuration M301.3 and M302.3 Location of the transfer supports shall be a minimum of 6 inches to a maximum of 19 inches from the top of the...
-
Gripping Surface Cross Section and Clearances M301, M302, and M305.2
Gripping Surface Cross Section and Clearances M301, M302, and M305.2 Gripping surface for transfer supports shall be free of sharp or abrasive elements and shall have rounded...
- Ascension 5442P Protege Chapter 2 Setup Operations and Performance Demonstration Video
-
f-ii
Is the change in level from the floor to the lift surface ramped or beveled? [ADA Standards §§ 4.11.2, 4.5.2] Yes No...
-
f-iii
Is there at least a 30-inch by 48-inch clear floor space on the wheelchair lift? [ADA Standards §§ 4.11.2, 4.2.4] Yes No...
-
M301.2.3.1 End Transfer Surface
imaging equipment with bores shall be permitted to be 21 inches (535 mm) wide minimum but shall not be permitted to be less than the full width of the examination surface provided for the patient...
-
M301.2.3.2 Side Transfer Surface
imaging equipment with bores shall be permitted to be 21 inches (535 mm) wide minimum but shall not be permitted to be less than the full width of the examination surface provided for the patient...
-
§ 38.159(b)(3) Emergency operation
The lift shall incorporate an emergency method of deploying, lowering to ground level with a lift occupant, and raising and stowing the empty lift if the power to the lift fails....
-
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. Transfer supports should be positioned 6 inches minimum and 19 inches maximum...
-
§ 38.125(b)(3) Emergency operation
The lift shall incorporate an emergency method of deploying, lowering to ground or station platform level with a lift occupant, and raising and stowing the empty lift if the power to the...
-
M301.2.4 Unobstructed Transfer
Each transfer surface shall provide two unobstructed sides for patient transfer. EXCEPTIONS: 1....
-
5.5.1 Armrest Provision for M302
5.5.1 Armrest Provision for M302 Description: Diagnostic equipment used by patients in a seated position such as exam chairs typically have armrests....
- Ascension Virtuoso 5460P Demonstration Video Chapter 3 Safety
- Ascension Virtuoso 5460P Demonstration Video Chapter 2 Setup Operations and Performance
- Ascension 5442P Protege Chapter 3 Safety Demonstration Video
- Ascension Virtuoso 5460P Demonstration Video Chapter 5 Options