Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2....
Search Results "Opening"
-
408.3.2 Swinging Doors
-
407.3.5 Door Delay
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
Doors at Entrances to Businesses
However, some older doors are less than 36 inches wide and may not provide enough width (32 inch clear width when fully opened). Door openings can sometimes be enlarged....
-
Flush Controls: ADA Standard Section 604.6
Section 604.6 covers the current ADA Standards for water closets flush controls.
-
11B-809.10.5.4 Bathtub enclosures
Hinged doors shall open outward. Glazing used in doors and panels of bathtub enclosures shall be fully tempered, laminated safety glass or approved plastic....
-
11B-809.10.5.4 Bathtub enclosures
Hinged doors shall open outward. Glazing used in doors and panels of bathtub enclosures shall be fully tempered, laminated safety glass or approved plastic....
-
Location of Controls
Comments indicated that this specification was not consistent with a corresponding figure showing the location on the side closest to the shower opening. Response....
-
Course Barriers
Where man-made barriers are provided that prevent golf cars from entering a fairway, openings at least 60 inches wide at intervals not exceeding 75 yards must be provided....
-
Accessible Entrances
This entrance must be open whenever other public entrances are open....
-
4.10.6* Door Protective and Reopening Device
Elevator doors shall open and close automatically....
-
4.10.6* DOOR PROTECTIVE AND REOPENING DEVICE
Elevator doors shall open and close automatically....
-
Doors and Gates in Series [§404.2.6]
This allows users to clear one door or gate before opening the next and applies to those doors or gates that are opposite each other where travel through both doors is required....
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
-
4.10.8 Door Delay for Car Calls
The minimum time for elevator doors to remain fully open in response to a car call shall be 3 seconds....
-
4.10.8 DOOR DELAY FOR CAR CALLS
The minimum time for elevator doors to remain fully open in response to a car call shall be 3 seconds....
-
1002.4.5 Ride Entry
Openings providing entry to wheelchair spaces on amusement rides shall be 32 inches (815 mm) minimum clear....
-
11B-1002.4.5 Ride entry
Openings providing entry to wheelchair spaces on amusement rides shall be 32 inches (813 mm) minimum clear....
-
Door Clear Width
Door Clear Width Open the door 90 degrees, measure from the face of the door to the edge of the door stop....
-
11B-1002.4.5 Ride entry
Openings providing entry to wheelchair spaces on amusement rides shall be 32 inches (813 mm) minimum clear....
-
11B-1002.4.5 Ride entry
Openings providing entry to wheelchair spaces on amusement rides shall be 32 inches (813 mm) minimum clear....
-
1002.4.5 Ride Entry
Openings providing entry to wheelchair spaces on amusement rides shall be 32 inches (815 mm) minimum clear....
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
1013.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically...
-
1007.3 Enclosed exit stairways
Exceptions: Open exit stairways as permitted by Section 1019.1 are permitted to be considered part of an accessible means of egress....