The 1½ inch clearance between walls and handrails is an absolute dimension; it provides knuckle clearance while preventing entrapment of the arm for people who lean on rails with their forearm...
Search Results "Maneuvering Clearance (Alcove)"
Commonly Searched Documents
-
Shape and Diameter
-
4.6.4 Clear Floor or Ground Space
Knee and toe clearance complying with ABAAS section 306 shall be provided under the telescope or periscope....
- Quadraplegic Transfer
-
How to do a Bed Transfer
Requires the Registered User plan or above. Login!
-
Transfer Demonstration from Wheelchair to Bed and Back to Wheelchair
Requires the Registered User plan or above. Login!
-
902.4.1 Clear Floor or Ground Space
Knee and toe clearance complying with 306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
902.4.1 Clear Floor or Ground Space
Knee and toe clearance complying with 306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
11B-902.4.1 Clear floor or ground space
Knee and toe clearance complying with Section 11B-306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
11B-902.4.1 Clear floor or ground space
Knee and toe clearance complying with Section 11B-306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
902.4.1 Clear Floor or Ground Space
Knee and toe clearance complying with 306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
Non-Circular Cross Section and Clearance (§505.5, §505.7)
Non-Circular Cross Section and Clearance (§505.5, §505.7)...
-
1134A.8, Item 4
4. Knee and toe space. Knee and toe space shall be provided by one of the following:
-
Obstructed Reach Depth
Obstructed Reach Depth
-
1134A.8, Item 4
4. Knee and toe space. Knee and toe space shall be provided by one of the following:
-
804.3.1 Clear Floor or Ground Space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with 306....
-
804.3.1 Clear Floor or Ground Space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with 306....
-
11B-804.3.1 Clear floor or ground space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with Section 11B-306....
-
11B-804.3.1 Clear floor or ground space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with Section 11B-306....
-
11B-804.3.1 Clear floor or ground space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with Section 11B-306....
-
804.3.1 Clear Floor or Ground Space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with 306....
-
806 Transient Lodging Guest Rooms
806 Transient Lodging Guest Rooms In the NPRM, the Department included floor plans showing examples of accessible guest rooms and bathrooms designs with mobility features to...
-
7(2)(b)
(b) Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet section 100.205(c)(3)(iv) if: Note: Clear floor space beside tub may overlap with clear floor...
-
28.1 Q. If an architect or builder chooses to follow the bathroom specifications in Requirement 7...are the other bathrooms in the dwelling unit required to have reinforced walls for grab bars?
A. Yes. Requirement 6 of the Guidelines requires reinforced walls in bathrooms for later installation of grab bars. Even though Requirement 6 was not repeated under Requirement...
-
4.4.2 Head Room
If vertical clearance of an area adjoining an accessible route is reduced to less than 80 in (nominal dimension), a barrier to warn blind or visually-impaired persons shall be provided (...