EXCEPTION: Within employee work areas, the required clear width of ramps that are a part of common use circulation paths shall be permitted to be decreased by work area equipment provided...
Search Results "Equipment Console"
Commonly Searched Documents
-
405.5 Clear Width
-
5.8.2 Knee and Toe Clearance Recommendations under Breast Platform Recommendations
Given the unique use of mammography equipment, the provision also contains a specific depth requirement under breast platforms....
-
5.8.3 Breast Platform Recommendations
clearance at the breast platform (see 5.8.2 Knee and Toe Clearance Recommendations under Breast Platforms), the height of the breast platform is also critical to ensuring that mammography equipment...
-
5.2.1.3 Transfer Surface Size Recommendations for Stretchers (M301)
The point of entry to the equipment is in the center. The length of the stretcher means a patient would transfer on in the middle....
- IDeA Center: Transferring from Wheeled Mobility to MidMark's Barrier-Free Examining Table
-
5.8.2.4 Unobstructed Floor Space Recommendation
Rationale for the recommendation The overall knee and toe clearance and unobstructed floor space dimensions dictate how close a patient in a wheelchair can get to the mammography equipment...
-
1.1 Recognizing the Barriers
Some of the common barriers experienced by people with disabilities 1,2 include: The fitness facility is not physically accessible The facility’s equipment and group classes...
-
Healthcare Stories - Alice Wong
Requires the Registered User plan or above. Login!
-
DREDF: Part 1 Barriers to Healthcare-Tables and Scales
Requires the Registered User plan or above. Login!
-
5.8.2.7 Base Support Allowance Recommendation
It does obstruct the floor space in front of the gantry and, thus, may limit how close a wheelchair can get to the equipment....
- American National Standard/AAMI HE75:2009/(R)2013 Human factors engineering – Design of medical devices
- National Alliance for Accessible Golf (Alliance)
- Thinking Out of the Box Engineering Applications (TOBEA)
- Challenged Athletes Foundation®
-
M303.2.5 Surfaces (Section-by-Section Analysis)
The MDE NPRM proposed to require diagnostic equipment used by patients seated in a wheelchair to provide a wheelchair space with a surface that does not slope more than 1:48 in any direction...
-
5.6.1 Stirrups Provision for M301
The Committee recommends where equipment provides stirrups, it must also provide an alternate method to support, position, and secure the patient’s legs (specifically including sufficient...
-
General: ADA Standard Section 205.1
Section 205.1 of the ADA Standards covers information on scoping requirements for operable parts in the most current ADA Standards.
-
M303.3 Entry
Where there is a change in level at the entry to wheelchair spaces, the change in level shall comply with M303.3.
-
M305.3.2 Height
The height of gripping surfaces for standing supports shall be based on the position of the standing supports in relation to the standing surfaces they serve. Horizontal standing...
-
M303.2.4.2.1 Depth
Wheelchair spaces shall include knee and toe clearance 17 inches (430 mm) deep minimum and 25 inches (635 mm) deep maximum.
-
M305.3.2 Height (Section-by-Section Analysis)
For horizontal supports, the MDE NPRM proposed a gripping surface height of 34 inches minimum and 38 inches maximum above the standing surface. There were no public comments on this...
-
§ 1194.23(k)
(k) Products which have mechanically operated controls or keys, shall comply with the following:
-
M303.3 Entry (Section-by-Section Analysis)
This is an introductory section.
-
5.8.1 Wheelchair Spaces on Raised Platforms
5.8.1 Wheelchair Spaces on Raised Platforms.