Transfer platforms shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
Search Results "Elevator Pit"
-
11B-1008.3.1.1 Size
-
11B-411.4.9 Emergency communication
Emergency communication shall comply with Section 11B-407.4.9.
-
11B-411.4.10 Support rail
Support rails complying with Section 11B-407.4.10 shall be provided on at least one wall of the car.
-
11B-411.4.3 Platform to hoistway clearance
Platform to hoistway clearance shall comply with Section 11B-407.4.3.
-
11B-411.4.8.2 Audible indicators
Audible indicators shall comply with Section 11B-411.4.8.2.
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section...
-
11B-407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of ½ inch (12.7 mm) under rated...
-
11B-409.4.7 Emergency communications
Emergency two-way communication systems shall comply with Section 11B-409.4.7.
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum.
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons.
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface.
-
11B-411.4.6.2 Buttons
Car control buttons shall comply with Sections 11B-407.4.6.2.1 and 11B-407.4.6.2.4. The car shall not have non-functional, exposed floor buttons.
-
Are public accommodations required to retrofit existing buildings by adding elevators?
Are public accommodations required to retrofit existing buildings by adding elevators?...
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-407.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-407.3.
-
11B-407.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-407.3.
-
11B-407.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-407.3.
-
408.4.1 Car Dimensions and Doors
Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum....
-
407.2.3.2 Car Designations
Destination-oriented elevators shall provide tactile car identification complying with 703.2 on both jambs of the hoistway immediately below the floor designation....
-
407.2.3.2 Car Designations
Destination-oriented elevators shall provide tactile car identification complying with 703.2 on both jambs of the hoistway immediately below the floor designation....
-
11B-407.4.10 Support rail
Support rails in elevator cabs are used in a different way than handrails along a walking surface such as a ramp or stairway. ...
-
11B-407.4.10 Support rail
Support rails in elevator cabs are used in a different way than handrails along a walking surface such as a ramp or stairway....