be accessible by first surveying the facility for code compliance and then making necessary corrections where public programs are provided and in employee common-use areas, restrooms, break...
Search Results "Break Out Opening"
Commonly Searched Documents
- 
    
  
  1.9.1.1.2
  
 - 
    
  
  C. Clear Floor Space
  
.: for out-swinging doors, at least 7'-0" between the exterior door frame and interior door frame) to allow persons who use wheelchairs to proceed through one door without it closing on...
 - 
    
  
  R304.1 General
  
There are two types of curb ramps: • Perpendicular curb ramps have a running slope that cuts through or is built up to the curb at right angles or meets the gutter break at right angles...
 - Disability Access - Tips for the small business
 - 
    
  
  4.20.2 Floor Space
  
However, because frail older adults do not perform sliding transfers, clear floor space in eldercare facilities was needed for one or more caregivers to be able to assist with getting in and out...
 - 
    
  
  Food and Beverage Service
  
provides both legal standards and promising practices for paths of travel, approach to dining spaces, seating, dining table and service counter heights, and other tips for making meal and break...
 - 
    
  
  Clear Width: ADA Standard Section 404.3.1
  
Section 404.3.1 covers the current ADA Standards for clear width at automatic and power-assisted doors and gates.
 - 
    
  
  11B-604.8.1.2 Doors
  
Where located in the front partition, the door opening shall be 4 inches (102 mm) maximum from the side wall or partition farthest from the water closet....
 - BlindNewWorld
 - 
    
  
  R304.5.5 Clear Space
  
Beyond the bottom grade break, a clear space 1.2 m (4.0 ft) minimum by 1.2 m (4.0 ft) minimum shall be provided within the width of the pedestrian street crossing and wholly outside the...
 - 
    
  
  Miniature Golf Course Configuration: ADA Standard Section 239.3
  
Section 239.3 covers scoping requirements in the current ADA Standards for miniature golf course configuration.
 - 
    
  
  11B-239.3 Miniature golf course configuration
  
Exception: One break in the sequence of consecutive holes shall be permitted provided that the last hole on the miniature golf course is the last hole in the sequence....
 - 
    
  
  1009.7.2 Separation
  
exterior wall construction shall extend horizontally 10 feet (3048 mm) beyond the landing on either side of the landing or equivalent fire-resistance-rated construction is permitted to extend out...
 - 
    
  
  11B-404.3.1 Clear width
  
Doorways shall provide a clear opening of 32 inches (813 mm) minimum in power-on and power-off mode....
 - 
    
  
  11B-409.3.1 Power operation
  
Power operated doors and gates shall remain open for 20 seconds minimum when activated....
 - 
    
  
  Willoughby Industries ETW-1490-FM-HC Floor Mount Wall Outlet Rear Mounted ADA Blow Out Type Flush Toilet
  Requires the Premium User plan or above. (Login or upgrade your account!)
 - 
    
  
  Attachment G: Modifications to Newly Constructed Facilities
  
Attachment G: Modifications to Newly Constructed Facilities
 - 
    
  
  Transfer Entry: ADA Standard Section 1002.5.3
  
Where openings are provided for transfer to amusement ride seats, the openings shall provide clearance for transfer from a wheelchair or mobility aid to the amusement ride seat....
 - 
    
  
  11B-1002.5.3 Transfer entry
  
Where openings are provided for transfer to amusement ride seats, the openings shall provide clearance for transfer from a wheelchair or mobility aid to the amusement ride seat....
 - 
    
  
  What if the Guidelines Appear To Conflict With Each Other?
  
Trash receptacles are supposed to be accessible so that everyone can use them, but then how do we keep bears out?...
 - 
    
  
  Power Operation: ADA Standard Section 409.3.1
  
Section 409.3.1 covers the current ADA Standards for the power operation of private residence elevator doors.
 - 
    
  
  THREATS AND HAZARDS IN NEW YORK CITY
  
Brush fires can also occur when temperatures climb and vegetation dries out, which puts the city’s grasslands at risk....
 - 
    
  
  POWER-ASSISTED DOOR
  
[DSA-AC] A door used for human passage with a mechanism that helps to open the door, or relieves the opening resistance of a door, upon the activation of a switch or a continued force applied...
 - 
    
  
  I have an accessible exam table, but if it is in use when a patient with a disability comes in for an appointment, is it OK to make the patient wait for the room to open up, or else use an exam table that is not accessible?
  
Q I have an accessible exam table, but if it is in use when a patient with a disability comes in for an appointment, is it OK to make the patient wait for the room to open up, or else use...