Size [§304.3] Turning space can be provided in the shape of a circle or a T. Elements with knee and toe space can overlap a portion of the turning space. Circular Turning...
Search Results "Bathtub Clearance"
Commonly Searched Documents
-
Size [§304.3]
-
Obstructed High Reach
The maximum reach of 48” is reduced to 44” when the depth of reach over an obstruction exceeds 20.” Knee and toe space must extend the full depth of reach.
-
1134A.8, Item 3
3. Cabinets. Cabinets under lavatories are acceptable provided the bathroom has space to allow a parallel approach by a person in a wheelchair and the lavatory cabinets are designed...
-
1133A.7.1 Plumbing protection
Water supply and drain pipes under kitchen sinks shall be insulated or otherwise covered to protect against contact. There shall be no sharp or abrasive surfaces under kitchen sinks.
-
11B-904.4.2 Forward approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum shall be provided. Knee and toe space complying with Section 11B-306...
-
11B-904.4.2 Forward approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum shall be provided. Knee and toe space complying with Section 11B-306...
-
1133A.7.1 Plumbing protection
Water supply and drain pipes under kitchen sinks shall be insulated or otherwise covered to protect against contact. There shall be no sharp or abrasive surfaces under kitchen sinks.
-
Handrails [4.8.5]
Since 1½ inch pipe has an outside diameter close to 2 inches, it is important that handrails mounted to walls still provide the 1½ inch (absolute) knuckle clearance....
-
Can clear floor/ground space or turning space overlap other space requirements?
Yes, clear floor or ground spaces and turning space can overlap other required clearances, including other clear floor spaces, door maneuvering clearances, and fixture clearances....
-
Guest Rooms with Mobility Features: ADA Standard Section 224.2
Section 224.2 covers scoping requirements in the current ADA Standards for transient lodging guest rooms with mobility features.
- Figure 307.4 Vertical Clearance – Drawing from the U.S. Access Board
- 307.4 Door Opening Vertical Clearance
-
Beds: ADA Standard Section 807.2.3
Where beds are provided, clear floor space complying with 305 shall be provided on at least one side of the bed. The clear floor space shall be positioned for parallel approach to...
-
11B-807.2.3 Beds
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed. The clear floor space shall be positioned for parallel...
-
11B-604.7.1 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the...
-
11B-405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by Sections 11B-404.2.4 and 11B-404.3.2 shall be permitted to overlap the required landing area....
-
5.8.2.1 Height of Breast Platform at Time of Measurement
The NPRM proposed measuring the knee clearance under the breast platform at 27 inches above the ground....
- Just Manufacturing Stainless Steel Cup Strainer ADA Compliant Drain System
- McGuire Manufacturing Co., Inc. 1151AWC: Offset with 151 Stainless Steel Basket Strainer
- McGuire Manufacturing Co., Inc. 155LATWC: Offset Lift and Turn PO Plug
- Bobrick B-3091 ClassicSeries® Recessed-Mounted Toilet Tissue, Seat-Cover Dispenser and Waste Disposal
- Bobrick B-3092 ClassicSeries® Recessed-Mounted Toilet Tissue, Seat-Cover Dispenser and Waste Disposal
-
4. Bed transfer space
4. Bed transfer space: A 30-inch by 48-inch clear floor space facilitates transfer from a wheelchair to the bed.
-
5. Bed with clear floor space
5. Bed with clear floor space for a side approach next to bed.