Hall signals, including in-car signals, shall comply with Section 11B-407.2.2.
Search Results "Altered Elevator"
-
11B-407.2.2 Hall signals
-
11B-407.4.6.2.1 Size and shape
11B-407.4.6.2.1 Size and shape. Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch...
-
11B-407.4.10.3 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, fastener, mounting...
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum. Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above...
-
11B-407.4.10.2 Surfaces
Support rails shall be smooth and any surface adjacent to them shall be free of sharp or abrasive elements.
-
216.7 Elevators
216.7 Elevators....
-
407.4.7 Designations and Indicators of Car Controls
EXCEPTION: In existing elevators, where a new car operating panel complying with 407.4.7 is provided, existing car operating panels shall not be required to comply with 407.4.7....
-
11B-407.4.7.1.3 Symbols
TABLE 11B-407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION Control Button Tactile Symbol Braille Message Emergency Stop...
-
11B-407.4.7.1.3 Symbols
TABLE 11B-407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION Control Button Tactile Symbol Braille Message Emergency Stop...
-
Connected Elevated Components
Connected Elevated Components When transfer systems are used, an elevated play component may connect to other elevated play components, providing an innovative, accessible route....
-
Savaria ORION Limited Use/Limited Application Elevator
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Visible Alarms in Alterations to Existing Facilities
Visible Alarms in Alterations to Existing Facilities....
-
11B-407.4.7 Designations and indicators of car controls
Exception: In existing elevators, where a new car operating panel complying with Section 11B-407.4.7 is provided, existing car operating panels may remain operational and shall not be required...
-
11B-407.4.7 Designations and indicators of car controls
Exception: In existing elevators, where a new car operating panel complying with Section 11B-407.4.7 is provided, existing car operating panels may remain operational and shall not be required...
-
11B-407.4.7 Designations and indicators of car controls
Exception: In existing elevators, where a new car operating panel complying with Section 11B-407.4.7 is provided, existing car operating panels may remain operational and shall not be required...
-
Technical Infeasibility
Compliance in an alteration is not required where it is “technically infeasible.”...
-
11B-233.3.4 Alterations
Alterations shall comply with Section 11B-233.3.4....
-
Frequency: ADA Standard Section 407.4.8.2.3
Section 407.4.8.2.3 covers the current ADA Standards for the frequency of audible elevator car indicators.
-
Common Questions (Elevators and Platform Lifts)
Common Questions
-
6.2.4 Beach Nourishment
Exception: No more than 20 percent of the costs of a facility construction or alteration project or beach nourishment project shall be required to be expended to provide beach access routes...
-
1008.2.5.2 Elevated
1008.2.5.2 Elevated. The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
F216.7 Elevators
Where existing elevators do not comply with 407, elevators complying with 407 shall be clearly identified with the International Symbol of Accessibility complying with 703.7.2.1....
-
216.7 Elevators
Where existing elevators do not comply with 407, elevators complying with 407 shall be clearly identified with the International Symbol of Accessibility complying with 703.7.2.1....
-
Triggering event. (Section-by-Section Analysis)
The Department is persuaded by the comments to adopt a two-pronged approach to defining the triggering event for new construction and alterations....