The provisions of this code shall apply to the construction, alteration, movement, enlargement, replacement, repair, equipment, use and occupancy, location, maintenance, removal and demolition...
Search Results "Shall"
-
1.1.3 Scope
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning...
-
1.9.1.1.4
Standards Code relating to access for persons with disabilities and other regulations adopted pursuant to Government Code Section 4450, and in effect at the time construction is commenced, shall...
-
11B-216.7 Elevators
Where existing elevators do not comply with Section 11B-407, elevators complying with Section 11B-407 shall be clearly identified with the International Symbol of Accessibility complying...
-
11B-809.5.2 Residential dwelling unit smoke detection system and carbon monoxide detection system
Residential dwelling unit smoke detection systems shall comply with Chapter 9, Section 907.2.11....
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
703.3.1 Dimensions and Capitalization
Braille dots shall have a domed or rounded shape and shall comply with Table 703.3.1....
-
809.4 Toilet Facilities and Bathing Facilities
At least one bathroom shall comply with 603. No fewer than one of each type of fixture provided shall comply with applicable requirements of 603 through 610....
-
407.3.4 Door and Signal Timing
time from notification that a car is answering a call or notification of the car assigned at the means for the entry of destination information until the doors of that car start to close shall...
-
809.4 Toilet Facilities and Bathing Facilities
At least one bathroom shall comply with 603. No fewer than one of each type of fixture provided shall comply with applicable requirements of 603 through 610....
-
407.3.4 Door and Signal Timing
time from notification that a car is answering a call or notification of the car assigned at the means for the entry of destination information until the doors of that car start to close shall...
-
F221.4 Designated Aisle Seats
At least 5 percent of the total number of aisle seats provided shall comply with 802.4 and shall be the aisle seats located closest to accessible routes....
-
R302.7.2 Vertical Surface Discontinuities
Vertical surface discontinuities shall be 13 mm (0.5 in) maximum....
-
221.4 Designated Aisle Seats
At least 5 percent of the total number of aisle seats provided shall comply with 802.4 and shall be the aisle seats located closest to accessible routes....
-
Facility
A clear floor space complying with 305 positioned for a forward approach shall be provided....
-
604.5.2 Rear Wall
The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
11B-404.3.2 Maneuvering clearance
Clearances at power-assisted doors and gates shall comply with Section 11B-404.2.4....
-
809.4 Toilet Facilities and Bathing Facilities
At least one bathroom shall comply with 603. No fewer than one of each type of fixture provided shall comply with applicable requirements of 603 through 610....
-
11B-208.1 General
Where parking spaces are provided, parking spaces shall be provided in accordance with Section 11B-208....
-
9.2.2(6)
(6) Where provided as part of an accessible unit, sleeping room, or suite, the following spaces shall be accessible and shall be on an accessible route: (a) the living area....
-
4.4.4 Clear Floor or Ground Space
A clear floor or ground space of 36 inches (915 mm) by 48 inches (1220 mm) shall be located at an end the bench with one side of the space adjoining an accessible route, outdoor recreation...
-
3.1 Disproportionate Costs for Small Projects
• "When the adjusted construction cost is less than or equal to the current valuation threshold, as defined in Chapter 2, Section 202, the cost of compliance with Section 11B-202.4 shall...
-
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls.
Minimum maneuvering clearances at doors that are not automatic or power-assisted shall be as shown in Fig. 25....