[DSA-AC] An amplification system utilizing transmitters, receivers, and coupling devices to bypass the acoustical space between a sound source and a listener by means of induction loop,...
Search Results "Urinal Clear Floor Space"
Commonly Searched Documents
-
ASSISTIVE LISTENING SYSTEM (ALS)
-
11B-502.8 Additional signs
shall be posted either; 1) in a conspicuous place at each entrance to an off-street parking facility or 2) immediately adjacent to on-site accessible parking and visible from each parking space...
-
ASSISTIVE LISTENING SYSTEM (ALS)
[DSA-AC] An amplification system utilizing transmitters, receivers, and coupling devices to bypass the acoustical space between a sound source and a listener by means of induction loop,...
-
2.2.3 Functional Reach
reach envelope required that the reach envelope be measured relative to certain environmental, wheelchair and personal features (e.g. 3-D envelopes measured relative to a point on the floor...
-
Problem Four (Accessible Route)
Or, if a church basement located down a flight of stairs is used as the voting area, perhaps one of the ground floor rooms could be used as the voting area....
-
1007.8 Exterior area for assisted rescue
This construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever is lower....
-
1003.2.13.7 Exterior area for assisted rescue
This construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever is lower....
-
B. Interior Ramps
(3) Third Floor North Corridor (Route to Fitness Center, Pool, and Spa) - This corridor will be modified so that its running slope does not exceed 1:20 (5%) or 1:12....
-
606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (865 mm) maximum above the finish floor or ground. EXCEPTIONS: 1....
-
608.5.2 Standard Roll-In Type Shower Compartments
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
Protruding Objects [4.4]
The standard sweep of canes allows detection of objects with leading edges up to 27 inches from the floor....
-
Scoping [4.1.3(8)]
number of public entrances (whichever is greater); and at least one entrance to each separate tenancy is accessible at least one accessible entrance serves the ground floor...
-
4.21.3 Seat
The seat shall be mounted 17 in to 19 in (430 mm to 485 mm) from the bathroom floor and shall extend the full depth of the stall....
-
4.10.14* EMERGENCY COMMUNICATIONS
The highest operable part of a two-way communication system shall be a maximum of 48 in (1220 mm) from the floor of the car....
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
11B-217.4 TTYs
Separate requirements are provided based on the number of public pay telephones provided at a bank of telephones, within a floor, a building, or on a site....
-
11B-217.4 TTYs
Separate requirements are provided based on the number of public pay telephones provided at a bank of telephones, within a floor, a building, or on a site....
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
§382.67(b)
(b) If you are a carrier that uses the seat-strapping method to stow a manual passenger wheelchair, you must ensure that there is priority space for at least two such wheelchairs, if stowing...
-
F.
Some complainants who use wheelchairs informed the United States that the wheelchair spaces available to them in some of Cinemark's auditoria with 300 seats or less were too close to the...
-
Definition [F106.5]
A picnic unit is an outdoor space in a picnic facility that is used for picnicking and contains at least one outdoor constructed feature....
-
Barriers to People with Disabilities
Barriers to People with Disabilities - characteristics of spaces, elements, or services covered under the ADA Regulations or ADA Standards for New Construction that do not comply with those...
-
Trailhead