The Elkay EZH2O Bottle Filling Station delivers a clean quick water bottle fill and enhances sustainability by minimizing our dependency on disposable plastic bottles....
Search Results "Water Closet Clear Floor Space"
- Elkay Filtered EZH2O® Bottle Filling Station Retro Fit Kit LMABFWS-RF
-
1132A.4, Item 1
impervious construction (e.g., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change in height between floor...
-
407.12.3.1 Unobstructed Forward Reach
maximum protrusion within the length of the vertical reference plane of the ICT, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high minimum above the floor...
-
11B-203.14 Raised diving boards and diving platforms
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
1132A.4, Item 1
impervious construction (e.g., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change in height between floor...
-
11B-203.14 Raised diving boards and diving platforms
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
11B.707.7.1.3 Horizontally mounted display screen
from the viewer 60 degrees to 90 degrees (horizontal) from vertical, the center line of the display screen and other display devices shall be no more than 34 inches (864 mm) above the floor...
- Verifone MX 925 Point of Sale Machine with Credit Card Reader
-
Is accessible parking required on sites where no parking is intended?
No, the ADA Standards require accessible spaces only where parking is provided. They do not require accessible spaces where parking is not provided at all....
-
Section 1630.2(j)(1)(i) Broad Construction; not a Demanding Standard
As Congress noted in the legislative history of the ADAAA, “[t]o be clear, the purposes section conveys our intent to clarify not only that ‘substantially limits’ should be measured by a...
-
Section 35.171 Acceptance of complaints. (Section-by-Section Analysis)
(Section-by-Section Analysis) In the NPRM, the Department proposed changing the current language in § 35.171(a)(2)(i) regarding misdirected complaints to make it clear that if an agency...
- Figure 802.2.1.1 Lines of Sight Over the Heads of Seated Spectators – Drawing from the U.S. Access Board
-
4.3.10* EGRESS
Accessible routes serving any accessible space or element shall also serve as a means of egress for emergencies or connect to an accessible place of refuge....
-
ADA Chapter 2: Scoping Requirements
These provisions specify which elements and spaces are required to be accessible according to various technical requirements contained in chapters 3 through 10....
-
4.1.6(4)(d)
(d) Doors. (i) Where existing elements prohibit strict compliance with the clearance requirements of 4.13.5, a projection of 5/8 in (16 mm) maximum will be permitted for the latch...
-
§ 38.153(c)
(c)
-
II-5.5000 Historic preservation programs
ILLUSTRATION: Installing an elevator in an historic house museum to provide access to the second floor bedrooms would destroy architectural features of historic significance on the first...
-
Section 4.1.6, Alterations (Preamble, Section-by-Section Analysis)
First, if any existing element or space is altered, the altered element or space must meet new construction requirements (section 4.1.6(1)(b))....
-
§100.205(c)(2)
(2) All the doors designed to allow passage into and within all premises are sufficiently wide to allow passage by handicapped persons in wheelchairs; and
- Hoyer Heavy-Duty Power Lift with Optional Scale
-
K. Ambulatory Stall
If there are more than 5 stalls in any restroom, is there one stall in addition to the large accessible stall, that is 36" wide, has 2 parallel grab bars at 33"-36" off the floor and has...
-
804.3.2 Height
The kitchen work surface shall be 34 inches (865 mm) maximum above the finish floor or ground....
-
11B-406.6 Islands
The clear width of the accessible route at islands shall be 60 inches (1524 mm) wide minimum. Where curb ramps are provided, they shall comply with Section 11B-406....