Some existing measurement protocols Currently there are no generally accepted measurement protocols for determining the slope, flatness, or waviness of floor surfaces in terms of accessibility...
Search Results "Water Closet Clear Floor Space"
-
Some existing measurement protocols
-
1009.8 Two-way communication
A two-way communication system complying with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is...
-
405.8 Handrails
Ramps not subject to the exception to 405.5 shall be designed to maintain a 36 inch (915 mm) minimum clear width when handrails are installed....
- Mats Inc. Grate Mat
-
11B-703.1.1.2 Inspection
The inspection shall include, but not be limited to, verification that Braille dots and cells are properly spaced and the size, proportion and type of raised characters are in compliance...
-
11B-703.1.1.2 Inspection
The inspection shall include, but not be limited to, verification that Braille dots and cells are properly spaced and the size, proportion and type of raised characters are in compliance...
- OPENspace
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground....
-
M302.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
General (R309.1) (Section-by-Section Analysis)
General (R309.1) (Section-by-Section Analysis) The technical requirements for accessible on-street parking spaces are contained in R309 and adapt the technical requirements for accessible...
-
Are bollards, poles, columns, or other elements permitted within the marked area of access aisles?
(The width of spaces and aisles is measured to the centerline of markings but can include the full line width where there is no adjacent parking space or aisle)....
-
216 Signs
Interior and exterior signs identifying permanent rooms and spaces shall comply with 703.1, 703.2, and 703.5....
-
B6
Does each accessible parking space have a sign with the symbol of accessibility that is visible when a vehicle is parked in the space? [ADA Standards § 4.6.4] Yes No...
- Otis Gen2 Elevator
-
Knowing audio description is present in the exhibition
A difference in floor texture could be used to cue visitors with vision loss where the panels with description buttons are located....
-
Audible Tones/Bells or Verbal Annunciators
...are all of the elevators equipped with audible tones/bells or verbal annunciators that designate the passage of floors?...
-
§100.201a(b)(1) ICC/ANSI A117.1-2003
National Standard: Accessible and Usable Buildings and Facilities, 2003 edition, (ICC/ANSI A117.1-2003), may be obtained from the International Code Council, 500 New Jersey Avenue, NW., 6th Floor...
-
11B.707.7.1.2 Angle-mounted display screen
away from the viewer 30 degrees to less than 60 degrees from vertical, the center line of the display screen and other display devices shall be no more than 44 inches (1118 mm) above the floor...
-
Museum Gift Shop
The 42" height of the main cashier counter and the 42 1/2" height of the second cashier counter exceed the maximum 36" allowable height above the finished floor....
-
11B-411.2.1.3.1 Keypad call console arrangement
The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
Flush Controls [4.18.4]
Flush Controls [4.18.4] Flush controls must be mounted no more than 44 inches above the finished floor and must: be automatic or operable by one hand operate without...
-
11B-411.2.1.3.2 Touch screen call console arrangement
The accessibility function button shall be located at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
11B-411.2.1.3.2 Touch screen call console arrangement
The accessibility function button shall be located at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....


