(c) In complying with paragraphs (a) and (b) of this section, a person providing intercity rail service may not provide more than two spaces to park wheelchairs nor more than two spaces...
Search Results "Centered Clear Floor Space"
Commonly Searched Documents
-
§ 37.91(c)
- Rebuilding Together Richmond - Richmond, VA
-
Sections 35.108(f) and 36.105(f)—Is Regarded as Having Such an Impairment
For example, if a daycare center refused to admit a child with burn scars because of the presence of the scars, then the daycare center regarded the child as an individual with a disability...
- Cybex Total Access Row/Rear Delt Exercise Machine
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground....
-
Seat Height
The proposed rule specified that the bench seat be 17 to 19 inches above the floor or ground (903.4)....
-
11B-904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
4. Grab Bars
Does the toilet in each accessible guestroom bathroom have a horizontal grab bar along the adjacent side wall that is at least 42" long and mounted 33"-36" above the floor for stabilization...
-
G. Compartment Size
If the accessible toilet is in a stall, does the stall measure at least 60" wide and 56" deep if it is wall mounted or 59" deep if it is floor mounted to allow persons who use wheelchairs...
-
217.4.1 Bank Requirement
EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY....
-
4.34.5.3 LAVATORY, MIRRORS, AND MEDICINE CABINETS
(3) If a medicine cabinet is provided above the lavatory, then the bottom of the medicine cabinet shall be located with a usable shelf no higher than 44 in (1120 mm) above the floor....
-
(1)(d)
Controls for flush valves should be mounted no more than 44 inches (1120 mm) above the floor....
-
§ 38.37(b)
(b) Controls required by paragraph (a) of this section shall be mounted no higher than 48 inches and no lower than 15 inches above the floor, shall be operable with one hand and shall not...
-
For EV with the charging port at rear of the vehicle, can EV be assumed to be able to back in the parking space for easy access to the charger at the head location?
RESPONSE: This practice is not regulated by the CBC Chapter 11B accessibility provisions. DSA is not aware of any restrictions on this practice.
-
Technical Memorandum TM 2012-05 Safe Harbor
In addition, information that an element or space constructed under the 1994 TAS may have been issued a variance does not mean that the element or space has been granted safe harbor....
-
Section 4.1.6, Alterations (Section-By-Section Analysis and Response to Comments)
First, if any existing element or space is altered, the altered element or space must meet new construction requirements (section 4.1.6(1)(b))....
-
609 Grab Bars
Specifications address size, spacing, position, surfaces, fittings, and structural strength....
-
1002 Amusement Rides
Provisions for amusement rides require either a wheelchair space on the ride, a ride seat designed for transfer, or a device designed for transfer to the ride....
-
208.2.3.1 Parking for Residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with 502 shall be provided for each residential dwelling unit required...
-
12162(a)(4)(A)(i)(III)
(III) space to park and secure a wheelchair is available in the dining car at the time such passenger wishes to eat (if such passenger wishes to remain in a wheelchair), or space to store...
-
Standards
Flatness and FL Floor Levelness Numbers ASTM E 1486 - 98 (2004) Standard Test Method for Determining Floor Tolerances Using Waviness, Wheel Path and Levelness Criteria ASTM...
- Storefront Improvement Program (SIP) - City of Cambridge, Massachusetts
-
Thresholds at Exterior Doors/Thresholds to Balconies or Decks
This was a particular concern among commenters from the South Florida building industry, who stated that the 3/4" height is ineffective for upper floors of high rise buildings in a coastal...
-
Conflict with Local Accessibility Codes
The commenter stated that the State of Washington's accessibility code may require installation of a ramp, and that the ramp may then create an accessible entrance for the ground floor,...