Tactile signs must include compliant raised characters and braille characters and be located at doors 48” to 60” above the floor or ground (§703.2)....
Search Results "Raised Character"
Commonly Searched Documents
-
Signs [ADA Standards §216, §703]
-
Signs
A, “ADA Standards for Accessible Design,” (Standards) § 4.1.3(16)(a): Raised and Braille letters or numbers (Standards § 4.30.4); Mounting location (§ 4.30.6); Color...
-
11B-703.6.3 Text descriptors
Text descriptors shall comply with Sections 11B-703.2 _|Signs; Raised Characters|_, 11B-703.3 _|Braille|_ and 11B-703.4 _|Installation Height and Location|_....
-
Jamb Signage
...are all elevator jambs provided with signs placed on both sides designating the floor with 2" minimum height raised letters and Braille characters centered at 60" above the finish floor...
-
11B-411.2.1.4.1.2 Identification
Buttons shall be identified by raised characters and symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
5e.
Are signs mounted on both sides of the elevator hoistway door opening that designate the floor with 2-inch minimum-height raised letters and Braille characters centered at 60 inches above...
-
11B-411.2.1.4.1.2 Identification
Buttons shall be identified by raised characters and symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
11B-411.2.1.4.1.2 Identification
Buttons shall be identified by raised characters and symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
3) Signs
"cafeteria this way;" "copy room") need not comply with requirements for raised and Brailled letters, but they must comply with requirements for character proportion, finish, and contrast...
- Designing Sidewalks and Trails for Access, Part II of II: Best Practices Design Guide
-
Pictograms and Symbols of Accessibility [ADA Standards §216.2 , §703.6, §703.7]
216.2 , §703.6, §703.7] Where pictograms are provided to identify a permanent room or space, such as a stairway, they must include text descriptors that comply with requirements for raised...
-
11B-703.6.3 Text descriptors
Text descriptors shall comply with Sections 11B-703.2 _|Signs; Raised Characters|_, 11B-703.3 _|Braille|_ and 11B-703.4 _|Installation Height and Location|_....
-
e-vi
Are signs mounted on both sides of the elevator hoist way door opening (for each elevator and at each floor) that designate the floor with 2-inch minimum-height raised letters and Braille...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
For example, the geometric symbol may be used as the sign background with raised characters and Braille per Sections 11B-703.2 and 11B-703.3. ◼...
-
11B-407.4.7.1.2 Location
Raised characters or symbols and Braille designations shall be placed immediately to the left of the control button to which the designations apply. Exception: Reserved....
-
1013.4, Item 5
Raised character and Braille exit signs shall comply with Chapter 11A, Section 1143A or Chapter 11B, Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5....
-
Sec.36.304(c)(2)
These measures include, for example, adjusting the layout of display racks, rearranging tables, providing Brailled and raised character signage, widening doors, providing visual alarms,...
-
§ 36.304(c)(2)
These measures include, for example, adjusting the layout of display racks, rearranging tables, providing Brailled and raised character signage, widening doors, providing visual alarms,...
-
Height Above Finish Floor or Ground: ADA Standard Section 703.4.1
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
11B-703.8.9 Height above floor
Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character....
-
11B-810.6.1 Entrances
Where signs identify a station or its entrance, at least one sign at each entrance shall comply with Section 11B-703.2 _|Signs; Raised Characters|_ and shall be placed in uniform locations...
-
11B-810.6.1 Entrances
Where signs identify a station or its entrance, at least one sign at each entrance shall comply with Section 11B-703.2 _|Signs; Raised Characters|_ and shall be placed in uniform locations...
- Innerface Signage Wave Interior Signage Series