to a table in an unsafe way....
Search Results "Play Table"
-
Boston Center for Independent Living, Inc.
-
902.4.1 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for forward approach shall be provided. Knee and toe clearance complying with 306 shall be provided, except that knee clearance 24...
-
11B-902.4.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for forward approach shall be provided. Knee and toe clearance complying with Section 11B-306 shall be provided, except...
-
11B-902.4.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for forward approach shall be provided. Knee and toe clearance complying with Section 11B-306 shall be provided, except...
-
902.4.1 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for forward approach shall be provided. Knee and toe clearance complying with 306 shall be provided, except that knee clearance 24...
-
902.4.1 Clear Floor or Ground Space
902.4.1 Clear Floor or Ground Space. A clear floor space complying with 305 positioned for forward approach shall be provided. Knee and toe clearance complying with 306 shall be...
-
Entry Points and Seats
Entry Points and Seats Entry points and seats are features of play components where individuals would transfer, sit, or gain access....
-
Miniature Golf Facilities: ADA Standard Section 206.2.16
Section 206.2.16 covers scoping requirements in the most current ADA Standards for accessible routes to miniature golf facilities.
-
Elements Within Picnic Units With Mobility Features [F245.2.5]
., picnic tables, grills) is provided within a picnic unit with mobility features, at least two of the same type of element must comply with the applicable technical requirements for that...
-
Accessible Surfaces Located In The Use Zone
The "use zone" is a ground level area beneath and immediately adjacent to a play structure or piece of equipment that is designated for unrestricted circulation around the equipment....
-
IV. ACCESSIBLE MEDICAL EQUIPMENT
encouraged to select such tables....
-
11B-206.2.16 Miniature golf facilities
Holes required to comply with Section 11B-239.2, including the start of play, shall be on an accessible route....
-
11B-206.2.16 Miniature golf facilities
Holes required to comply with Section 11B-239.2, including the start of play, shall be on an accessible route....
-
5.1* General
Where fixed tables (or dining counters where food is consumed but there is no service) are provided, at least 5 percent, but not less than one, of the fixed tables (or a portion of the dining...
-
Connected Elevated Components
Connected Elevated Components When transfer systems are used, an elevated play component may connect to other elevated play components, providing an innovative, accessible route....
-
5.1 GENERAL
In addition to the requirements of 4.1 to 4.33, the design of at least 5 percent of all fixed seating or tables in a restaurant or cafeteria shall comply with 4.32....
-
1008.4.4 Entry Points and Seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
1008.4.4 Entry Points and Seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
- Brewer Assist Power Procedure Table
- IDeA Center: Transferring from Wheeled Mobility to MidMark's Barrier-Free Examining Table
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
1008.4.4 Entry Points and Seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...