If exceptions are permitted to the minimum width and depth of wheelchair spaces on raised platforms, the technical criteria would specify the minimum and maximum height for any edge protection...
Search Results "Platform Height"
Commonly Searched Documents
-
Exceptions Considered for Wheelchair Spaces on Raised Platforms
-
Height
The Access Board is considering whether 6 inches minimum and 19 inches maximum above the transfer surface would be an appropriate height for transfer supports on diagnostic equipment used...
-
11B-206.7.8 Play areas
Platform lifts shall be permitted to provide accessible routes to play components or soft contained play structures....
-
Height: ADA Standard Section 704.4.1
Advisory 704.4.1 Height....
-
Components: ADA Standard Section 402.2
Section 402.2 covers the current ADA Standards for components of an accessible routes.
-
11B-206.2.6 Performance areas
Performance areas, including but not limited to, stages, platforms and orchestra pits, are treated as raised or lowered areas within a given story and all are required to be accessible by...
-
5.1.4 Transfer Surface Height Measurement for M301 and M302
5.1.4 Transfer Surface Height Measurement for M301 and M302 The Committee recommends capturing the transfer surface height at the highest point of the seat in an uncompressed state, inclusive...
-
11B-221.2.4 Temporary structures
Wheelchair spaces shall not be located on, or be obstructed by, temporary platforms or other movable structures....
-
602.4 Spout Height
Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground.
-
602.4 Spout Height
Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground.
-
4.15.2* Spout Height
Spouts shall be no higher than 36 in (915 mm), measured from the floor or ground surfaces to the spout outlet (see Fig. 27(a)).
-
4.15.2* SPOUT HEIGHT
Spouts shall be no higher than 36 in (915 mm), measured from the floor or ground surfaces to the spout outlet (see Fig. 27(a)). Figure 27 Drinking Fountains and Water...
-
11B-402.2 Components
consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared sides, elevators, and platform...
-
U.S. Access Board Medical Diagnostic Equipment Mammography Subcommittee Report:
U.S. Access Board Medical Diagnostic Equipment Mammography Subcommittee Report: Final Recommendations on Equipment Criteria
- Steelcase OLOGY Desk - Electric Rectangular Desk with Rail, Power Access and Up/Down Controller
-
5.8.1 Wheelchair Spaces on Raised Platforms
5.8.1 Wheelchair Spaces on Raised Platforms....
-
Height: ADA Standard Section 1009.4.2
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck....
-
10.3.1(9)
(9) In stations covered by this section, rail-to-platform height in new stations shall be coordinated with the floor height of new vehicles so that the vertical difference, measured when...
-
Mounting Height and Location
Section 703.4 covers the mounting height and location of signs with tactile characters....
-
5. Edge Protection
high edge protection on the back of the platform opposite the entry ramp and on the two sides of the platform, and for double ramped entry platforms, the Committee recommended a minimum...
-
Can platform lifts be portable or provided after construction as an adaptation?
Platform lifts must be permanent and installed at the time of construction or alteration with few exceptions....
-
1132A.4, Item 3
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 4 inches (101.6 mm)....
- Smith System Husky Square Activity Table
-
5.8.1.1 Clear Platform Size
5.8.1.1 Clear Platform Size. The platform should be a minimum clear width of 32-inches and a minimum clear length of 40-inches....