Elevator hoistway and car doors shall open and close automatically....
Search Results "Opening"
-
11B-411.3.2 Operation
-
1134A.6, Item 1.2
1.2 The shower stall shall measure at least 30 inches deep by 60 inches wide (762 mm by 1524 mm) with an entrance opening of at least 60 inches (1524 mm)....
-
Error/Omission: The door to the toilet room swings into the required clear floor space at accessible fixtures, controls, and dispensers.
Result: The entry door to the toilet room cannot be fully opened when a wheelchair user is using the accessible fixture, control, or dispenser....
-
11B-404.3 Automatic and power-assisted doors and gates
Automatic and power-assisted doors are often used by designers to provide accessibility when door closer pressure would exceed the allowable opening force for interior or exterior doors....
-
11B-404.3 Automatic and power-assisted doors and gates
Automatic and power-assisted doors are often used by designers to provide accessibility when door closer pressure would exceed the allowable opening force for interior or exterior doors....
-
1132A.3 Width and height of interior doors and secondary exterior doors
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
Temporary Solutions for Election Day: Accessible Entrance to Polling Place
Problem Four: Entrance door to the building is heavy and difficult to open. Suggestion: Keep the door propped open or station volunteers near the door to open it for voters....
-
Turnstiles and Security Gates at Entrances
Eliminating the barrier caused by a turnstile may be accomplished by simply removing the turnstile and leaving the opening....
-
T502.3.1 Clear Width
Doorways shall provide a clear opening of 32 inches (810 mm) minimum....
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
Amenities
Door openings shall provide a clear width of 32 inches minimum....
-
11B-404.3 Automatic and power-assisted doors and gates
Automatic and power-assisted doors are often used by designers to provide accessibility when door closer pressure would exceed the allowable opening force for interior or exterior doors....
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
-
704.1 General
Exterior walls shall be fire-resistance rated and have opening protection as required by this section....
-
Doors at Entrances to Businesses
However, some older doors are less than 36 inches wide and may not provide enough width (32 inch clear width when fully opened). Door openings can sometimes be enlarged....
-
Flush Controls: ADA Standard Section 604.6
Section 604.6 covers the current ADA Standards for water closets flush controls.
-
11B-809.10.5.4 Bathtub enclosures
Hinged doors shall open outward. Glazing used in doors and panels of bathtub enclosures shall be fully tempered, laminated safety glass or approved plastic....
-
11B-809.10.5.4 Bathtub enclosures
Hinged doors shall open outward. Glazing used in doors and panels of bathtub enclosures shall be fully tempered, laminated safety glass or approved plastic....
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
408.3.2 Swinging Doors
Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2....
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
407.3.5 Door Delay
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
408.3.2 Swinging Doors
Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2....