The requirement for a minimum 48 inch width between handrails is specific to stairs adjacent to areas of rescue assistance and does not apply generally to stairs covered by 4.9....
Search Results "Handrail Diameter"
Commonly Searched Documents
-
Egress Stairs
-
11B-707.9.1.1 Tactilely discernible numerical keypad
A tactilely discernible numerical keypad similar to a telephone keypad containing a raised dot with a dot base diameter between 1.5 mm and 1.6 mm and a height between 0.6 mm and 0.9 mm on...
-
1016.6 Openings
Openings in the surface of outdoor recreation access routes shall not allow the passage of a sphere more than 1/2 inch (13 mm) in diameter. Advisory 1016.6 Openings. ...
-
Controls
Recommendations: Buttons and plates should be raised or flush and at least ¾ inch in diameter (as specified for elevator control panels)....
-
1016.6 Openings
Openings in the surface of outdoor recreation access routes shall not allow the passage of a sphere more than 1/2 inch (13 mm) in diameter. Advisory 1016.6 Openings....
-
11B-707.9.1.1 Tactilely discernible numerical keypad
A tactilely discernible numerical keypad similar to a telephone keypad containing a raised dot with a dot base diameter between 1.5 mm and 1.6 mm and a height between 0.6 mm and 0.9 mm on...
-
11B-407.4.7.2 Keypads
The dot shall be 0.118 inch (3 mm) to 0.120 inch (3.05 mm) base diameter and in other aspects comply with Table 11B-703.3.1....
-
1005.3 Edge Protection
Where railings, guards, or handrails complying with 1005.2 are provided, edge protection complying with 1005.3.1 or 1005.3.2 shall be provided. Advisory 1005.3 Edge Protection....
-
1005.3 Edge Protection
Where railings, guards, or handrails complying with 1005.2 are provided, edge protection complying with 1005.3.1 or 1005.3.2 shall be provided. Advisory 1005.3 Edge Protection....
-
1003.2.13.2 Enclosed stairways
An enclosed stairway, to be considered part of an accessible means of egress, shall have a clear width of 48 inches (1219 mm) minimum between handrails and shall either incorporate an area...
-
1005.3 Edge Protection
Where railings, guards, or handrails complying with 1005.2 are provided, edge protection complying with 1005.3.1 or 1005.3.2 shall be provided. Advisory 1005.3 Edge Protection....
-
1007.8.2 Exterior exit stairway
Exterior exit stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1219 mm) between handrails....
-
§ 38.155(b)
(b) Where provided within passenger compartments, handrails or stanchions shall be sufficient to permit safe on-board circulation, seating and standing assistance, and alighting by persons...
- Rebuilding Together Portland - Portland, OR
-
11B-1005.3 Edge protection
Where railings, guards, or handrails complying with Section 11B-1005.2 are provided, edge protection complying with Section 11B-1005.3.1 or 11B-1005.3.2 shall be provided....
-
Edge Protection
Edge Protection Where railings, guards, or handrails are provided, edge protection must be provided and extend a minimum of 2 inches above the ground or deck surface....
-
11B-1005.3 Edge protection
Where railings, guards, or handrails complying with Section 11B-1005.2 are provided, edge protection complying with Section 11B-1005.3.1 or 11B-1005.3.2 shall be provided....
-
11B-1005.3 Edge protection
Where railings, guards, or handrails complying with Section 11B-1005.2 are provided, edge protection complying with Section 11B-1005.3.1 or 11B-1005.3.2 shall be provided....
-
11B-405.9 Edge protection
Exceptions: Edge protection shall not be required on ramps that are not required to have handrails and have sides complying with Section 11B-406.2.2....
-
11B-407.4.7.2 Keypads
The dot shall be 0.118 inch (3 mm) to 0.120 inch (3.05 mm) base diameter and in other aspects comply with Table 11B-703.3.1 _|Braille Dimensions|_....
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3 _|Platform to Hoistway Clearance|_,...
-
Openings [1017.6]
Openings in the surfaces of trails, passing spaces, and resting intervals must be small enough so that a sphere more than one-half inch in diameter cannot pass through....
-
7.4.7 Openings
Openings in trail tread surfaces, trail resting spaces, and trail passing spaces shall be small enough to prevent passage of a 1/2 inch- (13 mm-) diameter sphere....
-
4.29.2* Detectable Warnings on Walking Surfaces
Detectable warnings shall consist of raised truncated domes with a diameter of nominal 0.9 in (23 mm), a height of nominal 0.2 in (5 mm) and a center-to-center spacing of nominal 2.35 in...