Where elevator call buttons or keypads are provided, they shall comply with Sections 11B-407.2.1 and 11B-309.4 _|Operation|_. [2010 ADAS] 407.2.1 Call Controls....
Search Results "Elevator Pit"
Commonly Searched Documents
- 
    
  
  11B-407.2.1 Call controls
  
 - 
    
  
  407.4.8 Car Position Indicators
  
Audible and visible car position indicators shall be provided in elevator cars....
 - 
    
  
  11B-407.2.1 Call controls
  
Where elevator call buttons or keypads are provided, they shall comply with Sections 11B-407.2.1 and 11B-309.4. [2010 ADA Standards] 407.2.1 Call Controls....
 - 
    
  
  11B-408.4.6 Car controls
  
Elevator car controls shall comply with Section 11B-407.4.6. Control panels shall be centered on a side wall....
 - 
    
  
  11B-408.4.6 Car controls
  
Elevator car controls shall comply with Section 11B-407.4.6. Control panels shall be centered on a side wall....
 - 
    
  
  11B-408.4.6 Car controls
  
Elevator car controls shall comply with Section 11B-407.4.6. Control panels shall be centered on a side wall....
 - 
    
  
  408.4.6 Car Controls
  
Elevator car controls shall comply with 407.4.6. Control panels shall be centered on a side wall....
 - 
    
  
  4.10.6* DOOR PROTECTIVE AND REOPENING DEVICE
  
Elevator doors shall open and close automatically....
 - 
    
  
  Leveling: ADA Standard Section 409.4.4
  
Section 409.4.4 covers the ADA Standards for the self-leveling feature in private residence elevators.
 - 
    
  
  11B-407.4.3 Platform to hoistway clearance
  
The clearance between the car platform sill and the edge of any hoistway landing shall be 1¼ inch (32 mm) maximum.
 - 
    
  
  11B-411.4.7.2 Location
  
Raised characters or symbols and Braille designations shall comply with Section 11B-407.4.7.1.2.
 - 
    
  
  11B-411.2.1.3 Arrangement
  
Hall call console arrangement of required features shall comply with Section 11B-411.2.1.3.
 - 
    
  
  11B-407.4.8.2 Audible indicators
  
Audible indicators shall comply with Section 11B-407.4.8.2.
 - 
    
  
  11B-409.4.4 Leveling
  
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions.
 - 
    
  
  11B-407.2.1.1 Height
  
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception:...
 - 
    
  
  11B-411.2.1 Hall call consoles
  
Hall call consoles shall comply with Sections 11B-411.2.1 and 11B-309.
 - 
    
  
  11B-411.2.1.4 Additional features
  
Hall call console additional features, if provided, shall comply with Sections 11B-309 and 11B-411.2.1.4.
 - 
    
  
  Audible Tones/Bells or Verbal Annunciators
  
...are all of the elevators equipped with audible tones/bells or verbal annunciators that designate the passage of floors?...
 - 
    
  
  407.4.8.2.1 Signal Type
  
EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz...
 - 
    
  
  407.4.8.2.1 Signal Type
  
[ECTCR UFAS 4.10.13] EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with...
 - 
    
  
  407.4.8.2.1 Signal Type
  
EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz...
 - 
    
  
  11B-409.4.6.1 Size
  
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension.
 - 
    
  
  409.4.6.1 Size
  
Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension.
 - 
    
  
  409.4.6.2 Location
  
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall.