- Figure 1003.3.1 (Exception 1) Clear Pier Space Reduction at Boat Slips – Drawing from the U.S. Access Board
- Figure 1003.3.2 (Exception 1) Clear Pier Space Reduction at Boarding Piers – Drawing from the U.S. Access Board
-
Clearance: ADA Standard Section 604.9.2
Section 604.9.2 covers the current ADA Standards for clearances around children's use water closets.
-
Seat Location: ADA Standard Section 1009.2.2
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (405 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
11B-604.9.2 Clearance
Clearance around a water closet shall comply with Section 11B-604.3.
-
11B-1009.2.2 Seat location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (406 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
11B-1009.2.2 Seat location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (406 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
11B-604.9.2 Clearance
Clearance around a water closet shall comply with Section 11B-604.3.
-
Transfer Space: ADA Standard Section 1009.5.2
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
Ground Level and Elevated Play Components: ADA Standard Section 1008.2.1
Accessible routes serving ground level play components and elevated play components shall be permitted to use the exceptions in 1008.2.1. EXCEPTIONS: 1....
-
Example of a Single-User Bathroom (with Roll-in Shower)
Example of a Single-User Bathroom (with Roll-in Shower) Clear space required at any fixture can overlap required clear floor spaces, turning space, and door maneuvering space....
-
Teeing Grounds: ADA Standard Section 238.2.1
Section 238.2.1 covers scoping requirements in the current ADA Standards for teeing grounds.
-
Range or Cooktop: ADA Standard Section 804.6.4
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306....
- Access Board: Clear Floor or Ground Space
-
11B-804.6.4 Range or cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with Section 11B-306....
-
11B-804.6.4 Range or cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with Section 11B-306....
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
Passing Space [§403.5.3]
Passing Space [§403.5.3] Passing space is required every 200 feet and must be provided as a 60” by 60” minimum space or as T-shaped space where each stem is at least 48” long....
-
Clear Width [1016.3]
The clear width of ORARs must be a minimum of 36 inches....
-
11B-403.5.2 Clear width at turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1219 mm) wide, clear width shall be 42 inches (1067 mm) minimum approaching the turn, 48...
-
11B-403.5.2 Clear width at turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1219 mm) wide, clear width shall be 42 inches (1067 mm) minimum approaching the turn, 48...
-
Clear Floor Space [4.34.2] and Reach Ranges [4.34.3]
Clear Floor Space [4.34.2] and Reach Ranges [4.34.3] Either a forward approach or a parallel approach to the ATM must be provided....
-
Clear Width of Circulation Paths and Maneuvering Clearances at Wheelchair Spaces
spaces....
-
11B-240.2.1 Ground level play components
Ground level play components shall be provided in the number and types required by Section 11B-240.2.1....