Refer to the following examples: Exam room - Exam rooms are required to provide a turning space, accessible handwashing fixture, and 36-inch wide access along the full length of each...
Search Results "WCAG: Web Content Accessibility Guidelines"
Commonly Searched Documents
-
11B-805.4.3 Turning space
-
3. Service Animals
.1366 Clean-up of spills of animal urine, feces, or other body substances can be accomplished with blood/body substance procedures outlined in the Environmental Services section of this guideline...
-
V. DEVELOPMENT OF DISABILITY-RELATED POLICIES AND PROCEDURES
Content of Policies and Procedures....
- GE® 27" Drop-In Electric Range JM250DFBB
- Mannington Mills All Star Collection Commercial Carpet
-
1003.1 Applicability
The general requirements specified in Sections 1003 through 1015 shall apply to all three elements of the means of egress system, in addition to those specific requirements for the exit access...
-
Application of ADA to places of lodging that contain individually owned units. (Section-by-Section Analysis)
, or homeowners associations to retain ownership of accessible units, and to impose accessibility requirements on individual owners who choose to place inaccessible units into a rental program...
-
Definitions of residential facilities and transient lodging. (Section-by-Section Analysis)
The Department said in the ANPRM that by applying the 2004 ADAAG residential facility guidelines to transient group homes, homeless shelters, halfway houses, and other social service establishments...
- New Mexico Division of Vocational Rehabilitation (NMDVR)
-
11B-221.3 Companion seats
People purchasing a ticket for an accessible seat may purchase up to three additional seats for their companions in the same row and these seats must be contiguous with the accessible seat...
- AJW Architectural Products U125 45 oz. Horizontal Liquid Soap Dispenser - Surface Mounted
- American Dryer, Inc Wall Guard Accessory
-
Parking: ADA Standard Section 216.5
Section 216.5 covers scoping requirements in the current ADA Standards for signs at parking.
-
Vanity Counter Top Space: ADA Standard Section 806.2.4.1
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
Section 36.406(e) Housing at a Place of Education
Although the 2004 ADAAG contains provisions for both residential facilities and transient lodging, the guidelines do not indicate which requirements apply to housing provided in an educational...
-
Wading Pools: ADA Standard Section 242.3
Section 242.3 covers scoping requirements in the current ADA Standards for wading pools.
-
30. - 34.
., with copies of construction contracts, photographs and/or design drawings) the corrections that have been made, document any training of employees that has occurred (by date and the content...
-
Installation of Test Surfaces
b) Measure EWF moisture content. c) Measure the binder as a proportion of EWF dry weight. d) Mix the EWF and binder using a mixing paddle....
-
Looking at Cal Green 5.106.5.3, we must provide the conduits and panel capacity for future installation for the required number of spaces (2 in this case). However, it is only when the equipment is to be installed that we need to refer to CBC and CEC. Section 11B-228.3.1 also reiterates this. Therefore, we would show the location of the conduit stub outs adjacent to 2 current parking spaces and would show space on the electric panel for the future equipment – and that is all. At this time, we do not need to show the requirements for EV accessibility when equipment is installed per Chapter 11B. Is my interpretation correct?
RESPONSE: CBC Chapter 11B accessibility provisions for EVCS apply when a project consists of one or more electric vehicle charging spaces served by an electric vehicle charger or other charging...
-
11B-806.2.4.1 Vanity counter top space
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
11B-224.2.2 More than fifty guest room facilities
Facilities with more than fifty guest rooms shall be treated separately for the purposes of determining the required number of accessible rooms and type of accessible bathing facility....
-
1009.6.1 Travel distance
The maximum travel distance from any accessible space to an area of refuge shall not exceed the exit access travel distance permitted for the occupancy in accordance with Section 1017.1....
-
11B-242.3 Wading pools
At least one accessible means of entry shall be provided for wading pools. Accessible means of entry shall comply with sloped entries complying with Section 11B-1009.3....
-
M301.4.1 Clearance in Base (Section-by-Section Analysis)
Additionally, the Access Board proposed to permit equipment components to be located within 8 inches maximum of the centerline of the clearance width. Id....