GUIDE AT A GLANCE
-
2.2.6 Door Use
The door use tasks required the use of three different doors in the building housing the IDeA Center....
-
1. INTRODUCTION
Signals generated by a loudspeaker or talker must often traverse a less than optimal acoustical space before being received by a listener....
-
Check-in:
Be specific about your needs, for example, I would like a room on the ground floor, I use a motorized wheelchair and will need assistance in an emergency evacuation, or I use a motorized...
-
604.8.3 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor. [ECTCR UFAS 4.25.3, Fig. 38, 4.23.9, 4.34.5.3(3)]...
-
11B-804.3.2 Height
The kitchen work surface shall be 34 inches (864 mm) maximum above the finish floor or ground....
-
1007.8.2 Directions
Directions for the use of the two-way communication system, instructions for summoning assistance via the two-way communication system and written identification of the specific story, floor...
-
405.9.2 Curb or Barrier
A curb or barrier shall be provided that prevents the passage of a 4 inch (100 mm) diameter sphere, where any portion of the sphere is within 4 inches (100 mm) of the finish floor or ground...
-
803.5 Coat Hooks and Shelves
Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground. [ECTCR UFAS 4.25.3, Fig. 38]...
-
804.3.2 Height
The kitchen work surface shall be 34 inches (865 mm) maximum above the finish floor or ground....
-
G. Self-serve Items
If a counter is used for serving breakfast or other food products, does it have at least a 36" long section that is no higher than 36" above the floor to allow persons who use wheelchairs...
-
405.9.2 Curb or Barrier
A curb or barrier shall be provided that prevents the passage of a 4 inch (100 mm) diameter sphere, where any portion of the sphere is within 4 inches (100 mm) of the finish floor or ground...
-
M15
all built-in dispensers, receptacles, or equipment mounted so the front does not extend more than 4 inches from the wall if the bottom edge is between 27 inches and 80 inches above the floor...
-
1(3)(a)(ii)
(ii) If the building elevator is provided as a means of access to dwelling units other than dwelling units on a ground floor, then the building is an elevator building which is a covered...
-
H14
all built-in dispensers, receptacles, or equipment mounted so the front does not extend more than 4 inches from the wall if the bottom edge is between 27 inches and 80 inches above the floor...
-
211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with 211....
-
AUTOMATIC DOOR
The switch that begins the automatic cycle may be a photoelectric device, floor mat, or manual switch mounted on or near the door itself (see power-assisted door)....
-
7.2 SERVICE COUNTERS
distribution of goods to the public, an auxiliary counter or a portion of the main counter shall be provided with a maximum height of between 28 in to 34 in (710 mm to 865 mm) above the floor...
-
11B-203.11 Water slides
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders or other means of reaching the raised elements...
-
11B-804.3.2 Height
The kitchen work surface shall be 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-804.3.2 Height
The kitchen work surface shall be 34 inches (864 mm) maximum above the finish floor or ground....
- Illinois/Iowa Center for Independent Living (IICIL) - Rock Island, IL
- Sesame Retractable Stairs with Lift
- Kohler Bellwether® 60" x 32" Alcove Bath