commercial building, hotel, motel, resort, recreational vehicle or mobile home park, campground, apartment house, condominium, townhouse, homeowner association, club, community building or area...
Search Results "Clear Floor Area"
Commonly Searched Documents
-
SECTION 3101B SCOPE
-
Subpart D -- New Construction and Alterations (Preamble, Section-by-Section Analysis)
Potential patrons of places of public accommodation, such as retail establishments, should be able to get to a store, get into the store, and get to the areas where goods are being provided...
-
105 Referenced Standards
Mechanical Engineers (ASME) for various elevators and platform lifts (105.2.2) American Society for Testing and Materials (ASTM) for use zones, play equipment, and accessible surfaces at play areas...
-
R305 Detectable Warning Surfaces (Section-by-Section Analysis)
At boarding platforms for buses and rail vehicles, detectable warning surfaces must extend the full length of the public use areas of the platform....
-
"Other Power-Driven Mobility Device" (Section-by-Section Analysis)
., Segway®), or any mobility aid designed to operate in areas without defined pedestrian routes." ...
-
11B-217.4.1 Bank requirement
[2010 ADAS] EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY. ...
-
M302.4.1 Clearance in Base
The base of the diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum...
-
M301.4.1 Clearance in Base
The base of diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
-
3. Lavatory knee clearance
faucet hardware, the following features need to be provided -- a 29-inch-high clearance under the front edge of the lavatory, the top of the bowl mounted no higher than 34 inches above the floor...
-
604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (355 mm) minimum and 19 inches (485 mm) maximum above the finish floor....
-
608.7 Thresholds
maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a 1/2 inch (13 mm) high threshold would disturb the structural reinforcement of the floor...
-
502.6 Identification
Signs shall be 60 inches (1525 mm) minimum above the finish floor or ground surface measured to the bottom of the sign. Advisory 502.6 Identification....
-
604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (355 mm) minimum and 19 inches (485 mm) maximum above the finish floor....
-
11B-411.2.1.7.3 Assignment by security credential
Upon presentation of security credential, the destination floor shall be confirmed by verbal announcement and on the display screen....
-
11B-604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (356 mm) minimum and 19 inches (483 mm) maximum above the finish floor....
-
1133A.3 Removable base cabinets
The finish floor beneath kitchen sinks and work surfaces shall be extended to the wall....
-
Verify Rough Plumbing
and drain. 11B-607.5 Installation height and location of shower controls. 11B-608.5 Location of shower drains and floor...
-
7.2(1)
services to the public, at least one of each type shall have a portion of the counter which is at least 36 in (915mm) in length with a maximum height of 36 in (915 mm) above the finish floor...
-
Verify Rough Plumbing
and drain. 11B-607.5 Installation height and location of shower controls. 11B-608.5 Location of shower drains and floor...
-
Signatures
2009 For the United States: Preet Bharara United States Attorney By: Li Yu Assistant United States Attorney 86 Chambers Street, 3rd Floor...
-
4.34.6.8* REFRIGERATOR/FREEZER
refrigerator/freezer type; or (2) Of the over-and-under type and meet the following requirements: (a) Have at least 50 percent of the freezer space below 54 in (1370 mm) above the floor...
-
M302.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
-
M301.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...