[See subsections ...]
Search Results "Accessibility Standard"
Commonly Searched Documents
-
QUESTIONS AND ANSWERS: ACCESSIBILITY REQUIREMENTS FOR EXISTING SWIMMING POOLS AT HOTELS AND OTHER PUBLIC ACCOMMODATIONS
-
Accessible Pathway & Corridor: Minimum Clear Floor Space Required for 360-degree Turn
This data depicts the amount of space required by users of wheeled mobility devices to perform a 360-degree turn. The bold dashed line in the table and figure indicates the...
-
CHAPTER 11B ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING
[See subsections ...]
-
CHAPTER 11B ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING
[See subsections ...]
- American Specialties 9014 Surface Mounted Horizontal Baby Changing Station
-
4.3.9 Doorway Design
They also demonstrated a need to make some improvements to standards to provide access for the broad population of wheeled mobility users....
- Mansfield Lavatory Grande Isle 2018HBNS
-
TEXT TELEPHONE
[DSA-AC] Machinery or equipment that employs interactive text-based communications through the transmission of coded signals across the standard telephone network....
-
106 Definitions
One commenter asked that the term public right-of-way be defined; others asked that various terms and words defined by the 1991 Standards, but which were eliminated from the 2010 Standards...
-
Develop a Transition Plan
Another reason to update or create a new transition plan is that we now have accessibility standards for recreation areas such as swimming pools, play areas, exercise equipment, team seating...
-
13.1 Q. Are the public and common use areas of a newly constructed development that consists entirely of buildings having four or more multistory townhouses, with no elevators, required to be accessible?
If there are no covered multifamily dwellings on a site, then the public and common use areas of the site are not required to be accessible....
-
229 Windows
229 Windows A new requirement at section 229.1 of the 2010 Standards provides that if operable windows are provided for building users, then at least one window in an accessible space...
-
6.10
are built in conformity with the seating plans for Future Construction Theaters, or with the provisions of this Consent Order for Future Construction Theaters satisfy the requirements Standard...
-
203.1 General
EXCEPTION: In new construction, full compliance with the requirements of these standards is not required where an entity can demonstrate that it is structurally impracticable to meet the...
-
Chapter 6 BUILDING AN EVACUATION PLAN FOR A PERSON WITH A COGNITIVE DISABILITY
All standard building egress systems require the ability to process and understand information in order to safely evacuate....
-
J. Valet Parking and New Parking Garage
Defendants agree to construct accessible parking spaces, entrances, and routes of travel as required by 2010 Standards §§ 208.1, 208.2, 208.2.4, 208.3.1, and 502.1-503.5, and to erect appropriate...
-
11B-603.5 Accessories
Where towel or sanitary napkin dispensers, waste receptacles, or other accessories are provided in toilet facilities, at least one of each type shall be located on an accessible route....
-
5. Costs of the Proposed Rule
The Preliminary RIA shows that the proposed standards and guidelines will likely increase compliance costs substantially when first implemented, but will thereafter result in only a small...
-
1 - Design and drawing
In the preamble adopting the 2004 guidelines as the 2010 Standards for Accessible Design the Department of Justice clarified Sections 104.1 and 104.1.1 saying that conventional industry...
-
11B-1009.2.1 Pool lift location
[2010 ADA Standards] 1009.2.1 Pool Lift Location. Pool lifts shall be located where the water level does not exceed 48 inches (1220 mm). Exceptions: 1. ...
-
11B-404.3.1 Clear width
[2010 ADA Standards] 404.3.1 Clear Width. Doorways shall provide a clear opening of 32 inches (815 mm) minimum in power-on and power-off mode....
-
708 Two-Way Communication Systems
These systems must provide audible and visual signals so that they are accessible to people with vision or hearing impairments....
-
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302
The Committee recommends following the Access Board’s proposal in the preamble discussion allowing a 1½-inch clearance....
-
III-7.7000 Alterations
Throughout ADAAG, there are numerous examples of areas where there are less stringent standards for alterations than for new construction....