A continuous and unobstructed path of vertical and horizontal egress travel from any occupied portion of a building or structure to a public way....
Search Results "Vertical Alignment"
-
MEANS OF EGRESS
-
11B-903.6 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
303 Changes in Level
Section 303 addresses vertical changes in level in floor or ground surfaces. No changes have been made to this section....
-
§ 1194.25(j)(1)
(1) The position of any operable control shall be determined with respect to a vertical plane, which is 48 inches in length, centered on the operable control, and at the maximum protrusion...
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
11B-903.6 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
5.4.5 Transfer Support Position Recommendation for M301 and M302
5.4.5 Transfer Support Position Recommendation for M301 and M302 Description: Transfer support position refers to the placement of the gripping surface within the minimum and maximum vertical...
-
Permanently Installed Systems
Vertical wheelchair lifts are differentiated from elevators because they are limited in the height of their vertical lift, are not enclosed, and do not go through a floor level....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
RECOMMENDED CHANGE
RECOMMENDED CHANGE Revise the Section 5.4.11 recommendation as follows: The Committee recommends transfer supports and connections contain the strength to resist vertical forces of...
- Cal-Royal Legacy Series Locksets
-
MEANS OF EGRESS
A continuous and unobstructed path of vertical and horizontal egress travel from any occupied portion of a building or structure to a public way....
-
11B-602.5 Spout location
The spout shall be located 15 inches (381 mm) minimum from the vertical support and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers. ...
-
Automatic Operation [4.10.2]
Self-leveling must correct the overtravel or undertravel of a car as it stops at a landing within a ½ inch vertical tolerance since changes in level greater than ½ inch can be troublesome...
-
5.4.11 Transfer Support Structural Strength Recommendations for M301 and M302
5.4.11 Transfer Support Structural Strength Recommendations for M301 and M302 Description: Transfer supports and their connections must be capable of resisting sufficient vertical and...
-
Protrusion Limits: ADA Standard Section 307.2
Section 307.2 covers the current ADA Standards for protrusion limits.
-
Gaps: ADA Standard Section 1002.4.3
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
11B-307.2 Protrusion limits
For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance....
-
11B-307.2 Protrusion limits
For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance....
-
11B-806.2.3.1 Personal lift device floor space
The clearance shall be parallel to the long side of the bed and extend under the bed to points horizontally 30 inches (762 mm), vertically 7 inches (178 mm) and not more than 12 inches (...