(a) Each car shall contain sign(s) which indicate that certain seats are priority seats for persons with disabilities and that other passengers should make such seats available to...
Search Results "Rail Station"
Commonly Searched Documents
-
§ 38.105(a)
-
§ 38.125(c)(1) Design load
(1) Design load. Ramps or bridge plates 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp or bridge plate distributed over an area of 26...
-
§ 38.125(c)(7) Stowage
(7) Stowage. A compartment, securement system, or other appropriate method shall be provided to ensure that stowed ramps or bridge plates, including portable ramps or bridge plates...
-
§ 38.117(b)
(b) All step edges and thresholds shall have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor,...
-
§ 38.111(b)
(b)
-
§ 38.125(d)(3) Other spaces
(3) Other spaces. Spaces for individuals who wish to transfer shall include a regular coach seat or dining car booth or table seat and space to fold and store the passenger's...
-
§ 38.125(c) Car ramp or bridge plate
(c) Car ramp or bridge plate—
-
§ 38.125(b)(12) Use by standees
(12) Use by standees. Lifts shall accommodate persons using walkers, crutches, canes or braces or who otherwise have difficulty using steps. The lift may be marked to indicate a...
-
§ 38.117(a)
(a) Floor surfaces on aisles, step treads and areas where wheelchair and mobility aid users are to be accommodated shall be slip-resistant.
-
§ 38.123(b)
(b) Restrooms required to be accessible shall be in close proximity to at least one seating location for persons using mobility aids complying with §38.125(d) of this part and shall...
-
§ 38.93(b) Passageways
(b) Passageways. A route at least 32 inches wide shall be provided from doors required to be accessible by paragraph (a)(1) of this section to seating locations complying with...
-
§ 38.93(a)(2)
(2) If doorways connecting adjoining cars in a multi-car train are provided, and if such doorway is connected by an aisle with a minimum clear width of 30 inches to one or more...
-
§ 38.83(c)(4) Ramp barriers
(4) Ramp barriers. Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off.
-
§ 38.125(b)(9) Platform deflection
(9) Platform deflection. The lift platform (not including the entrance ramp) shall not deflect more than 3 degrees (exclusive of car roll) in any direction between its unloaded...
-
§ 38.125(b)(1) Design load
(1) Design load. The design load of the lift shall be at least 600 pounds. Working parts, such as cables, pulleys, and shafts, which can be expected to wear, and upon which the lift...
-
§ 38.95(b)(7) Platform gaps
(7) Platform gaps. Any openings between the lift platform surface and the raised barriers shall not exceed 5/8 inch wide. When the lift is at car floor height with the inner barrier...
-
11B-705.1.2.1 Platform edges
Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform.
-
11B-247.1.2.1 Platform edges
Platform boarding edges shall have detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.1.
-
[F] 907.4.2.2 Height
[F] 907.4.2.2 Height. The height of the manual fire alarm boxes shall be a minimum of 42 inches (1067 mm) and a maximum of 48 inches (1219 mm) measured vertically, from the floor...
-
ACCESSIBLE ROUTE & PATH OF TRAVEL QUESTIONS:
[See subsections ...]
-
There does not seem to be a distinction between different EVCS standards (Level 1, Level 2, DC CHAdeMO, DC CCS, and Tesla). Does the schedule defined in Table 11B-228.3.2.1 make a distinction between the different types of EVSE standards or are that all considered to equivalently be an EVCS?
RESPONSE: The CBC Chapter 11B accessibility requirements for EVCS do not distinguish between the different EVCS standards like those listed. However, building officials may view...
-
907.2.7 Group M
A manual fire alarm system shall be installed in Group M occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit...
-
907.2.7.1 Occupant notification
During times that the building is occupied, in lieu of the automatic activation of alarm notification appliances, the manual fire alarm system shall be allowed to activate an alarm...
-
11B-812.7.3 Lettering
The words “NO PARKING” shall be painted on the surface within each access aisle in letters a minimum of 12 inches (305 mm) in height and located to be visible from the adjacent...