Openings in exterior walls in adjacent stories shall be separated vertically to protect against fire spread on the exterior of the buildings where the openings are within 5 feet (1524 mm...
Search Results "Open Movie Captioning"
-
704.9 Vertical separation of openings
- The Wayfindr Open Standard
-
1. Rulemaking History Prior to the 2010 ANPRM
In the 2008 NPRM, the Department stated that it was considering options under which it might require movie theaters to exhibit movies that are captioned for patrons who are deaf or hard...
-
4. Benefits—Qualitative Discussion of Benefits
captioning or audio description, offer open captioning but only at inconvenient times (such as the middle of the day during the week), or offer captioning or audio description for only...
-
Exterior Routes
EXTERIOR ROUTES Floor and ground surfaces stable, firm and slip resistant. 11B-302.1 Openings in floor or ground...
-
Exterior Routes
EXTERIOR ROUTES Floor and ground surfaces stable, firm and slip resistant. 11B-302.1 Openings in floor or ground...
-
3. Benefits—Qualitative Discussion of Benefits
disabilities currently have consistent access to movie theaters that provide closed captioning and audio description. ...
-
a. Summary of Reasons for Proposed Regulation
Summary of Reasons for Proposed Regulation Because the Department’s rationale for proposing these requirements for movie captioning and audio description have already been discussed in...
-
411.1.2 Pass-Through of Closed Caption Data (Section-by-Section Analysis)
411.1.2 Pass-Through of Closed Caption Data (Section-by-Section Analysis) This section proposes that, where audio-visual players and displays process video with synchronized audio, cabling...
-
A. Prior to 2010
While the 2004 ANPRM did not mention movie captioning or audio description, several commenters suggested that the Department issue a rule regulating these features....
-
Automatic Door Break Out Openings
Automatic Door Break Out Openings. The 1991 Standards do not contain any technical requirement for automatic door break out openings....
-
3. Costs—Summary of Likely Economic Impact
The analysis assumes that no single-auditorium movie theater is already equipped to provide closed movie captioning or audio description....
-
Narrative description. (Section-by-Section Analysis)
As with captioning, the same two issues arise with this technology: the cost and the change to digital movies and projectors. ...
-
411 Closed Caption Processing Technologies (Section-by-Section Analysis)
411 Closed Caption Processing Technologies (Section-by-Section Analysis) This is an introductory section....
-
711.4.4 Ducts and air transfer openings
Penetrations of horizontal assemblies by ducts and air transfer openings that are not required to have dampers shall comply with this section....
-
g. Discussion of Significant Regulatory Alternatives That Minimize Impact on Small Entities
As detailed earlier in this preamble (see section IV, Section–by–Section Analysis, “Movie Captioning—Coverage, supra), the Department is proposing that all movie theaters covered by the...
-
Openings, Width and Length of Wheelchair Space
Openings, Width and Length of Wheelchair Space Openings and the width and length of wheelchair spaces need to be considered in relation to each other....
-
2. b. i. Clear door openings
Clear door openings: Door openings should provide a clear width of 32 inches (815 mm) minimum....
-
709.8 Duct and air transfer openings
Penetrations by duct and air transfer openings shall comply with Sections 711 and 715....
-
413 User Controls for Captions and Audio Description (Section-by-Section Analysis)
413 User Controls for Captions and Audio Description (Section-by-Section Analysis) This is an introductory section....
-
3.3 Lexington Woodhill Movies 10, 425 Codell Drive Lexington, Kentucky
3.3 Lexington Woodhill Movies 10 425 Codell Drive Lexington, Kentucky - In Auditoria 3 and 10, the four (4) wheelchair spaces shall be relocated one row farther back in the auditorium...
-
711.3.3 Ducts and air transfer openings
Penetrations of fire-resistance-rated walls by ducts and air transfer openings that are not protected with fire dampers shall comply with this section....
-
Open Discussion (Earle Kennett, Moderator)
Comment and Question by Earle Kennett: Unless I’m mistaken, we didn’t have any other prepared remarks for this panel, but we will now open [the panel for discussion]....
- Horton Automatics Engineered with Purpose