Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor.
Search Results "Occupied Unit"
-
1133A.5 Lower shelving
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor. Latching and locking doors that are...
-
1132A.7 Type of lock or latch
The type of latch and lock required for all doors shall be in accordance with Section 1132A.8 and Chapter 10, Section 1008.
-
1136A.1 Receptacle heights
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall be located no more than 48 inches (1219 mm) measured from the top of...
-
1133A.2.1 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, countertop or the face of any appliance (excluding handles and controls) that projects into the kitchen and...
-
Research Projects
The Board sponsors and coordinates research for use in developing accessibility guidelines and providing technical assistance to the public. The Board’s research program is focused...
-
809.5.1.2 Activation
All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the portion...
-
1011.7 Outdoor Rinsing Showers
Outdoor rinsing showers shall provide at least one hand-held shower spray unit with a hose 59 inches (1500 mm) long minimum....
-
1011.7 Outdoor Rinsing Showers
Outdoor rinsing showers shall provide at least one hand-held shower spray unit with a hose 59 inches (1500 mm) long minimum....
-
F233.3.3.1 Alterations to Vacated Buildings
Where a building is vacated for the purposes of alteration, at least 5 percent of the residential dwelling units shall comply with 809.2 through 809.4 and shall be on an accessible route...
-
1132A.2 Interior doors and secondary exterior doors
The provisions of this section shall apply to the dwelling unit side of doors leading from the interior of the dwelling unit to an unfinished basement or an attached garage....
-
1132A.2 Interior doors and secondary exterior doors
The provisions of this section shall apply to the dwelling unit side of doors leading from the interior of the dwelling unit to an unfinished basement or an attached garage....
-
11B-708.4.2 Residential dwelling unit interface
11B-708.4.2 Residential dwelling unit interface....
-
11B-809.5.2.1 Activation
All visible alarm appliances provided within the residential dwelling unit for smoke detection notification shall be activated upon smoke detection. ...
-
11B-809.5.2.1 Activation
All visible alarm appliances provided within the residential dwelling unit for smoke detection notification shall be activated upon smoke detection....
-
1(1)(a) Separate ground floor unit entrances
(a) Separate ground floor unit entrances....
-
1132A.2 Interior doors and secondary exterior doors
The provisions of this section shall apply to the dwelling unit side of doors leading from the interior of the dwelling unit to an unfinished basement or an attached garage....
-
11B-809.5.1.1 Alarm appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with Chapter 9, Section 907.5.2.3.3....
-
Doors in a Series
Doors in a series are not typically part of an individual dwelling unit. Doors in a series generally are used in the entries to buildings, and are therefore part of public spaces....
-
Requirement 4 -- Accessible Route Into and Through the Unit
[See subsections ...]
-
11B-809.5.1.1 Alarm appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with Chapter 9, Section 907.5.2.3.4 _|Visible alarms;...
-
11B-809.5.1.1 Alarm appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with Chapter 9, Section 907.5.2.3.3 _|Visible alarms;...
-
General: ADA Standard Section 409.1
Section 409.1 of the ADA Standards covers information in the current ADA Standards for private residence elevators.
-
25.1 Q. It appears from Figure 2(c) of the Guidelines (under Requirement 5) that there is a 34 inch height requirement for kitchen counters and vanities. Is this true?
A. No. Requirement 7 addresses the requirement for usable kitchens and bathrooms so that a person in a wheelchair can maneuver about the space. The legislative history of the Fair...