The MDE Advisory Committee recommended changing the breast platform height requirement from a specified height range to a required minimum range bounded by a required high height of 42 inches...
Search Results "Lavatory Height"
Commonly Searched Documents
-
4. Breast Platform Adjustability
-
M301.2.1 Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in the supine, prone, or side-lying position of 17 inches minimum and 19 inches maximum....
-
1134A.7, Item 3
Seat height. The minimum height of water closet seats shall be 15 inches (381 mm) above the floor....
-
1134A.7, Item 3
Seat height. The minimum height of water closet seats shall be 15 inches (381 mm) above the floor....
-
11B-504.2 Treads and risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum....
-
11B-504.2 Treads and risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum....
-
11B-504.2 Treads and risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum....
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface. EXCEPTION: Where a guard complying with sections...
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface. EXCEPTION: Where a guard complying with sections...
-
11B-213.2.1 Unisex (single-use or family) toilet and unisex bathing rooms
Unisex toilet rooms shall contain not more than one lavatory, and not more than two water closets without urinals or one water closet and one urinal....
-
11B-703.5.5 Character height
11B-703.5.5 Character height. Minimum character height shall comply with Table 11B-703.5.5....
-
402.4 Characters (Section-by-Section Analysis)
In addition, where ICT does not provide a screen enlargement feature, characters would be required to have a minimum height requirement of 3/16 inch based on the uppercase letter “I.”...
- Pressalit Care MATRIX LARGE Wash Basin with Overflow and Integrated Handrail
-
Addendum D: Comparison of demographics and transfer height between Phase 1 and Phase 2 of the study
[See subsections ...]
- Pressailt Care MATRIX ANGLE Wash Basin with Overflow Right-Facing with Integrated Handrail
-
M301.2.2 Sunset Provision (Section-by-Section Analysis)
(Significant Changes – Transfer Surface Adjustability), this is a new provision that was added to the final rule in conjunction with the new requirement of a low height range in M301.2.1...
-
11B-703.5.5 Character height
Minimum character height shall comply with Table 11B-703.5.5....
-
11B-703.5.5 Character height
Minimum character height shall comply with Table 11B-703.5.5....
- Populas Infinity Workstation
-
11B-703.4.1 Height above finish floor or ground
[2010 ADA Standards] 703.4.1 Height Above Finish Floor or Ground....
-
Knee and Toe Space [§305.4 and §306]
It is required at some elements, such as drinking fountains and lavatories, so that people using wheelchairs can pull up to them. Toe Space Knee Space...
- Symmons Ultra-Sense Battery Powered Sensor Faucet S-6060
-
Example of a Single-User Bathroom (with Roll-in Shower)
Where clear floor space at a lavatory is obstructed on both sides more than 2 feet, a clearance at least 36 inches wide is required....