Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
Search Results "High Energy Door"
Commonly Searched Documents
-
1132A.4.1 Thresholds
-
6.3(1)
(1) Each bedroom shall have a door that complies with 4.13....
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
-
Doors [9.2.2(3), 9.4]
Doors [9.2.2(3), 9.4] Compliance with 4.13 is required for all doors and doorways designed to allow passage into and within all sleeping suites or other units required to be accessible...
- Haws Barrier-Free Chilled Dual Wall Mount Fountain H1011.8HPS
-
11B-404.2.4 Maneuvering clearances
Minimum maneuvering clearances at doors and gates shall comply with Section 11B-404.2.4....
-
4.13.2 Revolving Doors and Turnstiles
Revolving doors or turnstiles shall not be the only means of passage at an accessible entrance or along an accessible route....
-
4.13.2 REVOLVING DOORS AND TURNSTILES
Revolving doors or turnstiles shall not be the only means of passage at an accessible entrance or along an accessible route....
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
Clear With [sic] [§404.2.3]
Clear With [sic] [§404.2.3] The clear width is measured from the stop to the face of doors or gates open 90⁰ (or to the leading edge of sliding or folding doors....
-
Door Opening Force
Door Opening Force If you’re using a door pressure gauge, place it where you would push open the door. ...
-
F206.4.1 Public Entrances
All public entrances provided in accordance with Paragraph F206.4.1 (Public Entrances) of the ABAAS must have at least one entrance door complying with Section 404.3 (Automatic and Power-Assisted...
-
11B-233.3.1.2.6.5 Additional requirements.
Interior door opening width complying with Section 11B-404.3.1. 3. Door and gate hardware complying with Section 11B-404.2.7. 4....
- ADAEZ Pro Plus Automatic Door Opener Programing the Operator Video
- ADAEZ Pro Plus Automatic Door Opener Mounting Template Video
- ADAEZ Pro Plus Automatic Door Opener Parts Description Video
-
T502.4 Doorways with Steps on Over-the-Road Buses
The door opening clear width above a height of 48 inches (1220 mm) measured from the lowest step tread shall be permitted to taper so as to reduce in width to 18 inches (457 mm) minimum....
-
Toilet Compartment Access
If the door and access were from the opposite side, although not as accessible I believe it is also §404 compliant because a self-closing door is not the same as a door with a closer? ...
- Doug Mockett & Company SDH1 Sliding Door Hardware
-
49 CFR Part 37 - Transportation for Individuals With Disabilities at Intercity, Commuter, and High Speed Passenger Railroad Station Platforms; Miscellaneous Amendments
DEPARTMENT OF TRANSPORTATION 49 CFR Parts 37 and 38 [Docket OST–2006–23985] RIN 2105–AD54 Transportation for Individuals With Disabilities at Intercity, Commuter, and High Speed...
-
4.1.3(7)(c)
(c) Each door that is an element of an accessible route shall comply with 4.13....
-
4.1.3(7)(d)
(d) Each door required by 4.3.10, Egress, shall comply with 4.13....
-
Minimum Clear Opening
The issue of minimum clear opening for doors was one of the most widely commented-upon design features of the guidelines....
-
(3) Doors within individual dwelling units
The final Guidelines recommend that doors intended for user passage within individual dwelling units have a clear opening of at least 32 inches nominal width when the door is open 90 degrees...