The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
Search Results "Head End Wall"
-
11B-809.10.7.1 Floor space
- Big John Toilet Support & Short Swivel Support 7.5" to 14" Installation Video
- Advent Sebring Wall Sconce with Emergency Battery Back-Up
-
DSA IR 16-12: GRAB BAR DESIGN AND CONNECTIONS: 2019 CBC
ACCEPTANCE: 2.1 Grab bars connected to structural walls, such as wood framed walls, metal stud partition walls, CMU, concrete or any other material covered by the code or a standard:...
-
Construction and Manufacturing Tolerances: ADA Standard Section 104.1.1
Section 104.1.1 of the ADA Standards covers the most current information on dimensions in regards to construction and manufacturing tolerances in the ADA Standards.
-
4.21.2 Size and Clearances
To this end, several projects incorporated a half height wall to enable a caregiver using a hand held shower to stay dry while standing behind a resident seated in a shower chair....
-
Rectangular Seats: ADA Standard Section 610.3.1
Section 610.3.1 covers the current ADA Standards for rectangular shower compartment seats.
-
11B-610.3.1 Rectangular seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall....
-
11B-610.3.1 Rectangular seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
Transfer Type Shower Compartments: ADA Standard Section 608.5.1
Section 608.5.1 covers the current ADA Standards for controls in transfer type shower compartments.
-
11B-608.5.1 Transfer type shower compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm...
-
11B-608.5.1 Transfer type shower compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm...
-
Location: ADA Standard Section 604.2
Section 604.2 covers the current ADA Standards for the mounting location of water closets.
-
Issue 12: Audible beaconing
In the pedhead-mounted APS models installed in the US over the past 30 years, sounds were broadcast simultaneously from overhead speakers at each end of the crosswalk and at two parallel...
-
Pass Through Kitchen: ADA Standard Section 804.2.1
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
11B-604.7.2 Disposal units
Sanitary napkin disposal units, if provided, shall comply with Section 11B-309.4 and shall be wall mounted and located on the sidewall between the rear wall of the toilet and the toilet...
-
11B-804.2.1 Pass through kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
11B-804.2.1 Pass through kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
11B-604.7.2 Disposal units
Sanitary napkin disposal units, if provided, shall comply with Section 11B-309.4 and shall be wall mounted and located on the sidewall between the rear wall of the toilet and the toilet...
-
A MINIMUM HIGHEST POINT STANDARD OF 19 INCHES IS CONSISTENT WITH EXISTING ACCESSIBILITY STANDARDS
Permanent seats shall be 15 inches (380 mm) minimum in depth and shall extend from the back wall to or beyond the outer edge of the bathtub....
- Sloan WETS 2050.1401-1.28 G2 OPTIMA Plus Systems Activated HET Flushometer and HET Wall Hung Water Closet
-
Bobrick ClassicSeries LiquidMate Wall-Mounted Soap Dispenser B-155 Elevations