Swinging hoistway doors shall open and close automatically and shall comply with Sections 11B-404, 11B-407.3.2 and 11B-408.3.2....
Search Results "Fire Door"
-
11B-408.3.2 Swinging doors
-
11B-408.3.2 Swinging doors
Swinging hoistway doors shall open and close automatically and shall comply with Sections 11B-404, 11B-407.3.2 and 11B-408.3.2....
-
11B-408.3.2 Swinging doors
Swinging hoistway doors shall open and close automatically and shall comply with Sections 11B-404, 11B-407.3.2 and 11B-408.3.2....
-
Residential Dwelling Units: ADA Standard Section 206.5.4
Section 206.5.4 covers scoping requirements in the most current ADA Standards for accessible routes to residential dwelling units.
-
1132A.10 Door signal devices
Every primary entrance to a covered multifamily dwelling unit shall be provided with a door buzzer, bell, chime or equivalent....
-
1132A.10 Door signal devices
Every primary entrance to a covered multifamily dwelling unit shall be provided with a door buzzer, bell, chime or equivalent....
-
Can handrails or other elements overlap door maneuvering clearances?
No, door maneuvering clearances must be free of any overlapping objects, even those providing knee and toe clearance, which can interfere with maneuvering at doors and doorways....
-
11B-206.5.4 Residential dwelling units
In residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, all doors and doorways providing user passage shall comply with Section...
-
11B-206.5.4 Residential dwelling units
In residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, all doors and doorways providing user passage shall comply with Section...
-
16. Opening Building Doors
For paratransit services, a passenger's request for the driver to open an exterior entry door to a building to provide boarding and/or alighting assistance to a passenger with a disability...
-
11B-215.5 Residential facilities
Where provided in residential dwelling units required to comply with Section 11B-809.5, fire alarms shall comply with Chapter 9, Section 907.5.2.3.3 and carbon monoxide alarms shall comply...
-
11B-215.5 Residential facilities
Where provided in residential dwelling units required to comply with Section 11B-809.5, fire alarms shall comply with Chapter 9, Section 907.5.2.3.3 and carbon monoxide alarms shall comply...
-
A4.13.11(3) Application of force
(3) Application of force: Apply force gradually so that the applied force does not exceed the resistance of the door....
-
A4.13.11(3) Application of force
(3) Application of force: Apply force gradually so that the applied force does not exceed the resistance of the door....
-
1132A.3, Item 4
A nominal 32-inch (813 mm) clear opening provided by a standard 6-foot wide (1829 mm) sliding patio door assembly is acceptable....
-
1132A.3, Item 4
A nominal 32-inch (813 mm) clear opening provided by a standard 6-foot wide (1829 mm) sliding patio door assembly is acceptable....
-
404.2.7 Door and Gate Hardware
Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 309.4....
-
11B-702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 and Chapter 9, Sections 907.5.2.1 and 907.5.2.3. [2010 ADAS] 702.1 General. ...
-
11B-702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 and Chapter 9, Sections 907.5.2.1 and 907.5.2.3. [2010 ADAS] 702.1 General....
-
11B-702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 and Chapter 9, Sections 907.5.2.1 and 907.5.2.3....
- TelCom Wheelock Wall Mount Chime - 24 VDC 15/75 on Axis Strobe Candela CH70-241575W-FR
-
Door Protective and Reopening Device [4.10.6]
Door reopening devices must be able to detect obstructions without contact; otherwise, they can disrupt the balance of people using crutches or canes....