If soap and towel dispensers are provided, they must be located within the reach ranges specified in Section 11B-308, except for those in toilet and bathing rooms which must comply with...
Search Results "Exception"
-
11B-606.1 General
-
11B-703.7.2.6.2 Women’s toilet and bathing facilities
Exception: Within secure perimeter of detention and correctional facilities, geometric symbols shall not be required to be ¼ inch (6.4 mm) thick....
-
11B-612.2 Bench
Exception: A readily removable bench shall be permitted to obstruct the turning space required by Section 11B-612.3 and the clear floor or ground space required by Section 11B-903.2....
-
1018.3 Aisles in Groups B and M
Exception: Nonpublic aisles serving less than 50 people and not required to be accessible by Chapter 11B, (see Section 11B-403) need not exceed 28 inches (711 mm) in width....
-
Clear Width: ADA Standard Section 405.5
Section 405.5 covers the current ADA Standards for the clear width requirements of ramps.
-
11B-612.2 Bench
Exception: A readily removable bench shall be permitted to obstruct the turning space required by Section 11B-612.3 and the clear floor or ground space required by Section 11B-903.2....
-
11B-703.7.2.6.2 Women’s toilet and bathing facilities
Exception: Within secure perimeter of detention and correctional facilities, geometric symbols shall not be required to be ¼ inch (6.4 mm) thick....
-
11B-306.3.4 Clearance reduction
Exception: The knee clearance shall not be reduced at built-in dining and work surfaces required to be accessible by Section 11B-226.1....
-
11B-407.2.2.1 Visible and audible signals
Exceptions: Reserved. Reserved. [2010 ADA Standards] 2. In existing elevators, a signal indicating the direction of car travel shall not be required....
-
11B-309.4 Operation
Exception: Gas pump nozzles and electric vehicle connectors shall not be required to provide operable parts that have an activating force of 5 pounds (22.2 N) maximum....
-
Spas: ADA Standard Section 242.4
Section 242.4 covers scoping requirements in the current ADA Standards for spas.
-
11B-407.4.8.2.1 Signal type
Exception: For elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum which sounds as the car passes or...
-
11B-206.5.3 Transient lodging facilities
Exception: Shower and sauna doors in guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall not be required to comply with Section 11B-404.2.3...
-
11B-306.3.4 Clearance reduction
Exception: The knee clearance shall not be reduced at built-in dining and work surfaces required to be accessible by Section 11B-226.1....
-
11B-309.4 Operation
Exception: Gas pump nozzles and electric vehicle connectors shall not be required to provide operable parts that have an activating force of 5 pounds (22.2 N) maximum....
-
11B-203.12 Animal containment areas
Public circulation routes where animals may also travel, such as in petting zoos and passageways alongside animal pens in State fairs, are not eligible for the exception. ◼...
-
Appendixes
Key Differences Between Routes Notification Forms Entire Trail Exemption Form [1017.2, Exception 2] Entire Beach Access Route Exemption Form [1018.2...
-
11B-407.4.6.2 Buttons
Exception: Reserved. [2010 ADA Standards] EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
11B-206.2.1 Site arrival points
Exceptions: 1. Reserved. [2010 ADA Standards] 1....
-
1008.2.2 Soft Contained Play Structures
Accessible routes serving soft contained play structures shall be permitted to use the exception in 1008.2.2....
-
A.3.iii - If an EIT item is maintained or developed by both contractor and government employees, is it covered by the Section 508 standards?
Unless an exception applies, if the product is a deliverable under a contract it must conform to the applicable standards regardless of the mix of labor used to produce it....
-
1008.2.2 Soft Contained Play Structures
Accessible routes serving soft contained play structures shall be permitted to use the exception in 1008.2.2....
-
11B-405.5 Clear width
Exceptions: Within employee work areas, the required clear width of ramps that are a part of common use circulation paths shall be permitted to be decreased by work area equipment...
-
11B-405.5 Clear width
Exceptions: Within employee work areas, the required clear width of ramps that are a part of common use circulation paths shall be permitted to be decreased by work area equipment...