When latch-side clearance is required as part of the maneuvering clearances specified for a door, including on the push side of doors with a forward approach that have both a closer and...
Search Results "Double Door"
Commonly Searched Documents
-
Is latch-side maneuvering clearance as specified in the Standards applicable to doors with panic bars?
- Eliason Corporation SCP-8 High Pressure Laminate Traffic Double Door
-
307.4 Vertical Clearance
EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground. Figure 307.4 Vertical Clearance...
-
1132A.5.2 Strike edge maneuvering space at doors
1132A.5.2 Strike edge maneuvering space at doors. The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]
- ADAEZ Pro Plus Automatic Door Opener Quick Tip Door Arm Pivot Variations Video
- ADAEZ Pro Plus Automatic Door Opener Quick Tip Adjusting Spring Door Tension Video
- Access Board: Automatic Door Controls
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
11B-307.4 Vertical clearance
Exception: Â Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground....
-
11B-307.4 Vertical clearance
Exception:  Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground.  ...
-
D3
[ADA Standards § 4.13.9]    Yes    No If No, leave door propped open, add new accessible hardware, or adapt/replace hardware.  ...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
- Boost Your Business - Chapter 6 - Doors
-
I. Security
Is the security latch or bolt on the hall door mounted no higher than 48" above the floor so it is within the reach of persons who use wheelchairs and is it operable with one hand, without...
-
g-ii
Is the door hardware (e.g., lever, pull, push, panic bar) usable with one hand, without tight grasping, pinching, or twisting of the wrist, to allow people who may not be able to easily...
- FlexCounterâ„¢ - Window Door Combination
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
- LaCantina Doors - Contemporary Clad Industrial