The tops of dining surfaces and work surfaces shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground.
Search Results "Door Height"
-
11B-902.3 Height
-
11B-902.3 Height
The tops of dining surfaces and work surfaces shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground.
-
11B-404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with Section 11B-404. Exceptions: 1. ...
-
11B-404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with Section 11B-404....
-
11B-408.3.2 Swinging doors
Swinging hoistway doors shall open and close automatically and shall comply with Sections 11B-404, 11B-407.3.2 and 11B-408.3.2....
-
11B-408.3.2 Swinging doors
Swinging hoistway doors shall open and close automatically and shall comply with Sections 11B-404, 11B-407.3.2 and 11B-408.3.2....
-
11B-408.3.2 Swinging doors
Swinging hoistway doors shall open and close automatically and shall comply with Sections 11B-404, 11B-407.3.2 and 11B-408.3.2....
-
Residential Dwelling Units: ADA Standard Section 206.5.4
Section 206.5.4 covers scoping requirements in the most current ADA Standards for accessible routes to residential dwelling units.
-
11B-504.2 Treads and risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum....
-
11B-504.2 Treads and risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum....
-
1132A.10 Door signal devices
Every primary entrance to a covered multifamily dwelling unit shall be provided with a door buzzer, bell, chime or equivalent....
-
1132A.10 Door signal devices
Every primary entrance to a covered multifamily dwelling unit shall be provided with a door buzzer, bell, chime or equivalent....
-
Can handrails or other elements overlap door maneuvering clearances?
No, door maneuvering clearances must be free of any overlapping objects, even those providing knee and toe clearance, which can interfere with maneuvering at doors and doorways....
-
11B-233.3.1.2.6.5 Additional requirements.
Interior door opening width complying with Section 11B-404.3.1. 3. Door and gate hardware complying with Section 11B-404.2.7. 4....
-
11B-206.5.4 Residential dwelling units
In residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, all doors and doorways providing user passage shall comply with Section...
-
11B-206.5.4 Residential dwelling units
In residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, all doors and doorways providing user passage shall comply with Section...
-
E. Door Pressure
Door Pressure (1) Defendants will perform door force checks on all public access doors and will adjust or modify as necessary to ensure that they do not require more than five (5) pounds...
-
16. Opening Building Doors
For paratransit services, a passenger's request for the driver to open an exterior entry door to a building to provide boarding and/or alighting assistance to a passenger with a disability...
-
T502.4 Doorways with Steps on Over-the-Road Buses
The door opening clear width above a height of 48 inches (1220 mm) measured from the lowest step tread shall be permitted to taper so as to reduce in width to 18 inches (457 mm) minimum....
-
Accessible Counter Height
Where only a portion of a counter is made accessible, these commenters advised that the maximum height should be 32 inches....
-
A4.13.11(3) Application of force
(3) Application of force: Apply force gradually so that the applied force does not exceed the resistance of the door....
-
A4.13.11(3) Application of force
(3) Application of force: Apply force gradually so that the applied force does not exceed the resistance of the door....
-
1010.1.7 Thresholds
Thresholds at doorways shall not exceed ¾ inch (19.1 mm) in height above the finished floor or landing for sliding doors serving dwelling units or ½ inch (12.7 mm) above the finished floor...