The International Symbol of TTY shall comply with Figure 11B-703.7.2.2.
Search Results "Directional Signage"
-
11B-703.7.2.2 International Symbol of TTY
-
11B-703.2.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”. [2010...
-
11B-810.6.3 Station names
Stations covered by this section shall have identification signs complying with Section 11B-703.5. Signs shall be clearly visible and within the sight lines of standing and sitting...
-
11B-703.6.3 Text descriptors
Pictograms shall have text descriptors located directly below the pictogram field. Text descriptors shall comply with Sections 11B-703.2, 11B-703.3 and 11B-703.4.
-
11B-703.2 Raised characters
Raised characters shall comply with Section 11B-703.2 and shall be duplicated in Braille complying with Section 11B-703.3. Raised characters shall be installed in accordance with...
-
11B-703.8.9 Height above floor
Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character. Heights of low resolution...
-
11B-216.8.3 Signs at toilet and urinal compartments
Where both toilet compartments and urinal compartments are provided, each individual compartment shall be identified with a sign complying with Sections 11B-703.1 through 11B-703.5....
-
11B-703.7.2.3 Volume control telephones
Telephones with a volume control shall be identified by a pictogram of a telephone handset with radiating sound waves on a square field such as shown in Figure 11B-703.7.2.3.
-
11B-703.2.2 Case
Characters shall be uppercase.
-
11B-302.3 Openings
Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel....
-
Openings in Beach Access Routes
Place elongated openings more than a quarter of an inch wide with the long dimension perpendicular or diagonal to the primary direction of travel (see figure 44)....
-
F216.9.1 Identification Signs
Public TTYs shall be identified by the International Symbol of TTY complying with 703.7.2.2.
-
216.9.1 Identification Signs
216.9.1 Identification Signs. Public TTYs shall be identified by the International Symbol of TTY complying with 703.7.2.2.
-
11B-216.9.1 Identification signs
Public TTYs shall be identified by the International Symbol of TTY complying with Section 11B-703.7.2.2.
-
1008.1.9.7, Item 5
5. A sign shall be provided on the door located above and within 12 inches (305 mm) of the release device reading: “KEEP PUSHING. THIS DOOR WILL OPEN IN 15 [30] SECONDS ALARM...
-
216.9.1 Identification Signs
Public TTYs shall be identified by the International Symbol of TTY complying with 703.7.2.2.
-
§ 38.27 Priority seating signs
[See subsections ...]
-
11B-216.9.1 Identification signs
Public TTYs shall be identified by the International Symbol of TTY complying with Section 11B-703.7.2.2.
-
11B-216.5.2.2 Additional signs
Signs within parking facilities containing parking spaces complying with Section 11B-502 shall comply with Section 11B-502.8.
-
11B-216.9.1 Identification signs
Public TTYs shall be identified by the International Symbol of TTY complying with Section 11B-703.7.2.2.
-
11B-216.5.2.2 Additional signs
Signs within parking facilities containing parking spaces complying with Section 11B-502 shall comply with Section 11B-502.8.
-
§ 382.51 Communicable diseases
carrier may take the actions listed in paragraph (a) of this section with respect to an individual who has a communicable disease or infection only if the individual’s condition poses a direct...
- Access Board: Tactile Sign Clear Floor Space
-
11B-216.4.2 Areas of refuge and exterior areas for assisted rescue
Signs required by Chapter 10, Section 1009.11 to provide instructions in areas of refuge shall comply with Section 11B-703.5. Signs required by Chapter 10, Section 1009.9 at doors to...