Search Results "Seating Space"
-
604.9 Water Closets and Toilet Compartments for Children’s Use
-
604.9 Water Closets and Toilet Compartments for Children's Use
Ages 9 through 12 Water Closet Centerline 12 inches (305 mm) 12 to 15 inches (305 to 380 mm) 15 to 18 inches (380 to 455 mm) Toilet Seat...
-
Appendix Three: Bibliography
Space Requirements for Wheeled Mobility Devices in Public Transportation: Analysis of Clear Floor Space Requirements....
-
If Carrier Contends That Attendant Is Required for Safety Reasons and Passenger Disagrees
[Sec. 382.35(c)] In addition, if no seat is available on the flight for the attendant whom the carrier has determined to be necessary and as a result the passenger with a disability with...
-
6.2. Scoping Requirements
In the 2014 NPRM, the Department proposed scoping requirements for captioning devices based on the number of seats in a movie theater. ...
-
ACCESSIBLE ROUTE
[DSA-AC & HCD 1-AC] A continuous unobstructed path connecting accessible elements and spaces of an accessible site, building or facility that can be negotiated by a person with a disability...
-
Areas of Sport Activity
Section 206.2.2 of the 2010 Standards requires at least one accessible route to connect accessible buildings, facilities, elements, and spaces on the same site....
-
11B-219.2 Required systems
In each assembly area where audible communication is integral to the use of the space, an assistive listening system shall be provided....
-
11B-804.2 Clearance
Exception: Spaces that do not provide a cooktop or conventional range shall not be required to comply with Section 11B-804.2. [2010 ADAS] Advisory 804.2 Clearance. ...
-
231 Judicial Facilities
revisions: provisions specific to courtrooms have been relocated without substantive change to a new technical section on courtrooms (808) in Chapter 8, which covers special rooms, spaces...
-
11B-703.5 Visual characters
by Braille complying with Section 11B-703.3, they shall not be required to comply with Sections 11B-703.5.2 through 11B-703.5.6, 11B-703.5.8 _|Stroke Thickness|_ and 11B-703.5.9 _|Line Spacing...
-
202 Existing Buildings and Facilities
Section 202.3 states that each altered element or space is required to meet the applicable scoping provisions of Chapter 2....
-
Definition of "Mezzanine"
definition used in the IBC: "An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than one-third of the area of the room or space...
-
1016.6 Openings
Spaces between the boards in a boardwalk and drainage grates are examples of openings. ...
-
Cognition and Emotional States
Life space shrinks down to very few social interactions....
-
Approach, Enter, and Exit
Access Board, “approach, enter, and exit” means that people using wheelchairs must be able to enter and back out of the space....
-
N. Health Units/Medical Care Areas
route and have accessible features, including an accessible entrance, an accessible route to the different types of services offered within the medical care unit, turning and maneuvering spaces...
-
Multiple Usable Entrances
However, the requirements for usable doors and an accessible route to exterior spaces such as balconies and decks does respond to this concern....
-
4.25.3 Height
Accessible storage spaces shall be within at least one of the reach ranges specified in 4.2.5 and 4.2.6 (see Fig. 5 and Fig 6)....
-
Audible Alarms [4.28.2]
The sound of the alarm must be able to be distinguished above and apart from the prevailing sound level within the space....
-
Controls
Clear floor space at controls should be located outside the door swing....
-
Egress, Means of
A means of egress comprises vertical and horizontal travel and may include intervening room spaces, doorways, hallways, corridors, passageways, balconies, ramps, stairs, enclosures, lobbies...
-
Controls [9.2.2(5)]
Controls [9.2.2(5)] All controls in accessible units, sleeping rooms, and suites must comply with 4.27, which provides specifications for clear floor space, height of operable controls...