PSE shall provide and maintain directional signage at inaccessible toilet rooms indicating the location of the nearest accessible toilet room on the Floor Level. ...
Search Results "Clear Floor Space"
-
C. Toilet Rooms:
- Rebuilding Together Peoria - Peoria, IL
- National Restaurant Association - Americans with Disabilities Act Toolkit
- AbilityApp
- Populas Infinity Workstation
- Mannington Mills Palma Collection Commercial Carpet
- Mannington Mills Vivendi Collection Commercial Carpet
-
Non-Positive Shut-off
Remember that the hose has to be at least 59" long so it would fall onto the floor of the tub if dropped. It's a plumbing safety requirement....
- Cybex Total Access Row/Rear Delt Exercise Machine
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground....
-
Seat Height
The proposed rule specified that the bench seat be 17 to 19 inches above the floor or ground (903.4)....
-
11B-904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
4. Grab Bars
Does the toilet in each accessible guestroom bathroom have a horizontal grab bar along the adjacent side wall that is at least 42" long and mounted 33"-36" above the floor for stabilization...
-
G. Compartment Size
If the accessible toilet is in a stall, does the stall measure at least 60" wide and 56" deep if it is wall mounted or 59" deep if it is floor mounted to allow persons who use wheelchairs...
-
217.4.1 Bank Requirement
EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY....
-
4.34.5.3 LAVATORY, MIRRORS, AND MEDICINE CABINETS
(3) If a medicine cabinet is provided above the lavatory, then the bottom of the medicine cabinet shall be located with a usable shelf no higher than 44 in (1120 mm) above the floor....
-
11B.707.7.1.3 Horizontally mounted display screen
from the viewer 60 degrees to 90 degrees (horizontal) from vertical, the center line of the display screen and other display devices shall be no more than 34 inches (864 mm) above the floor...
-
(1)(d)
Controls for flush valves should be mounted no more than 44 inches (1120 mm) above the floor....
-
§ 38.37(b)
(b) Controls required by paragraph (a) of this section shall be mounted no higher than 48 inches and no lower than 15 inches above the floor, shall be operable with one hand and shall not...
-
11B-502.6 Identification
NOTES 11B-502.6 Identification Amends current regulations to require the International Symbol of Accessibility at accessible parking spaces...
-
B5
Are all accessible parking spaces, including the access aisle, relatively level (1:50 or 2%) in all directions?...
-
1017.6 Openings
This section requires openings in the surface of trails, passing spaces, and resting intervals such as spaces between the boards in a boardwalk to not allow passage of a sphere more than...
-
ESSENTIAL FEATURES
Those elements and spaces that make a building or facility usable by, or serve the needs of, its occupants or users....