Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
Search Results "Vehicle Pull-Up Space"
Commonly Searched Documents
-
306.3.3 Minimum Required Depth
-
F230.1 General
This requirement applies to facilities such as office buildings, courthouses, and other facilities where admittance to the building or restricted spaces is dependent on two-way communication...
-
306.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
-
Transfer Platform
That provides enough room for a person transferring to maintain balance and provides enough space to maneuver on top of it....
-
230.1 General
This requirement applies to facilities such as office buildings, courthouses, and other facilities where admittance to the building or restricted spaces is dependent on two-way communication...
-
11. Toilet rooms and bathing facilities
Accessible element or space ANSI A117.1 section APPLICATION 11....
-
Section 2. Common use areas
"Common use areas" means rooms, spaces or elements inside or outside of a building that are made available for the use of residents of a building or the guests thereof....
-
806.2 Guest Rooms with Mobility Features
The requirements in 806.2 do not include requirements that are common to all accessible spaces....
-
7.4.9 Trail Facilities
When the surface of the required clear ground space for trail facilities is not paved or is not elevated above the natural ground, slopes not steeper than 1:20 (5 percent) shall be permitted...
-
Note
Please note that this is not an exhaustive list of the elements and spaces required to be accessible per the 2013 California Building Code. ...
-
R304.3.2 Running Slope
The running slope of the turning space shall be 2 percent maximum....
-
306.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
-
4.34.2(9)
(9) All controls in accessible spaces shall comply with 4.27....
-
Note
Please note that this is not an exhaustive list of the elements and spaces required to be accessible per the 2013 California Building Code. ...
-
306.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
-
Common Use Circulation Paths in Employee Work Areas [§206.2.8]
This requirement facilitates access to individual work stations within a space. Common Use Circulation Paths...
-
Additions [§202.2]
Existing elements and spaces affected by an addition are treated as alterations and qualify for certain allowances or exceptions that are not permitted in new construction....
-
Can platform lifts be portable or provided after construction as an adaptation?
Platform lifts can be provided after construction only to provide access to raised work stations in courtrooms (sufficient space and electrical service must be provided in design to facilitate...
-
Can ramps be portable or provided after construction as an adaptation?
Ramps can be provided after construction only to provide access to raised work stations in courtrooms (sufficient space must be provided in design to facilitate installation)....
-
11B-806.2 Guest rooms with mobility features
The requirements in Section 11B-806.2 do not include requirements that are common to all accessible spaces....
- Hafele America Co. Wall Mounted Comfort Folding Shower Seat
-
11B-1002.2 Accessible routes
In most cases, this will be limited to areas where the accessible route leads directly to the amusement ride and where there are space limitations on the ride, not the queue line....
-
11B-809.10.6.1 Size
A water closet shall be permitted to project 12 inches (305 mm) maximum into the opening provided that 36 inches (914 mm) minimum clear space is maintained between the water closet and the...
-
Assessment factors. (Section-by-Section Analysis)
, all-terrain vehicle (ATV), golf car, or other device with a fuel-powered or combustion engine....