It has enough storage space inside to hold your valued possessions away from sight....
Search Results "Lavatory Clear Floor Space"
Commonly Searched Documents
- Mesa Safe Company MP101 Pedestal Electronic Hotel Safe
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
11B-406.6 Islands
The clear width of the accessible route at islands shall be 60 inches (1524 mm) wide minimum. Where curb ramps are provided, they shall comply with Section 11B-406....
-
Security Bollards [7.4] and Security Devices
Security Bollards [7.4] and Security Devices Bollards and rails used to keep shopping carts on the premises must allow an accessible clear passage (32 inches wide minimum) along at least...
-
4.8.4 LANDINGS
(2) The landing length shall be a minimum of 60 in (1525 mm) clear....
-
11B-707.7.1.1 Vertically mounted display screen
mounted vertically or no more than 30 degrees tipped away from the viewer, the center line of the display screen and other display devices shall be no more than 52 inches (1321 mm) above the floor...
-
603.4 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor. [ECTCR UFAS 4.25.3, Fig. 38]...
-
11B.707.7.1.2 Angle-mounted display screen
mounted between 30 degrees and 60 degrees tipped away from the viewer, the center line of the display screen and other display devices shall be no more than 44 inches (1118 mm) above the floor...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
407.8.3.1 Unobstructed Forward Reach
maximum protrusion within the length of the vertical reference plane of the ICT, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high minimum above the floor...
-
M20
Is there a horizontal grab bar at least 36 inches long securely mounted behind the toilet 33 to 36 inches above the floor with one end no more than 6 inches from the side wall?...
-
Free-standing and Post-mounted Objects
Where objects are mounted above 27 inches from the ground or floor, overhangs are limited to 12 inches. This is based on standard measures for cane sweep....
-
§ 38.113(d)(4) Exception
Retrofitted vehicles shall be coordinated with the platform in existing stations such that the horizontal gap shall be no greater than 4 inches and the height of the vehicle floor, under...
-
11B.707.7.1.1 Vertically mounted display screen
mounted vertically or tipped away from the viewer less than 30 degrees, the center line of the display screen and other display devices shall be no more than 52 inches (1321 mm) above the floor...
-
Section 1630.2(j)(1)(i) Broad Construction; not a Demanding Standard
As Congress noted in the legislative history of the ADAAA, “[t]o be clear, the purposes section conveys our intent to clarify not only that ‘substantially limits’ should be measured by a...
-
General Regulatory Approach
We must structure our response to this mandate in a way that allows for clear and consistent implementation by the carriers, and clear and consistent enforcement by the Department....
-
R210.3 Shared Use Paths
require objects along or overhanging any portion of a pedestrian circulation path to comply with the proposed technical provisions for protruding objects in R402 and to not reduce the clear...
-
Section 35.171 Acceptance of complaints. (Section-by-Section Analysis)
(Section-by-Section Analysis) In the NPRM, the Department proposed changing the current language in § 35.171(a)(2)(i) regarding misdirected complaints to make it clear that if an agency...
-
11B-405.7.5 Doorways
Where a door swings onto a ramp landing width, additional ramp landing length as specified may be necessary to accommodate a clear level area for the wheelchair user to clear the door swing...
-
Storage: ADA Standard Section 225.2
Section 225.2 covers scoping requirements in the current ADA Standards for storage.
-
11B-703.1.1.2 Inspection
The inspection shall include, but not be limited to, verification that Braille dots and cells are properly spaced and the size, proportion and type of raised characters are in compliance...
-
TECHNICALLY INFEASIBLE
alteration of a load-bearing member that is an essential part of the structural frame, or because other existing physical or site constraints prohibit modification or addition of elements, spaces...