The proposed rule did not provide any specific restrictions regarding surface hazards around the transfer supports....
Search Results "Transfer Surface"
-
M305.2.5 Surface Hazards (Section-by-Section Analysis)
-
Platform Height
Platform Height Transfer platforms must be between 16 and 19 inches high, measured from the deck....
-
Height
Height The transfer wall height must be 16 inches minimum to 19 inches maximum, measured from the deck....
-
11B-608.2.1 Reserved
ETA Editor's Note The transfer type shower compartments prescribed by 2010 ADAS 608.2.1 are not recognized as an accessible shower in California....
-
1009.4.2 Height
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
405.4 Floor or Ground Surfaces
Floor or ground surfaces of ramp runs shall comply with 302. Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
405.4 Floor or Ground Surfaces
Floor or ground surfaces of ramp runs shall comply with 302. Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
Highway standards suggesting possible applications for pedestrian surfaces
ASTM E 950-98(2004) Standard test method for measuring the longitudinal profile of traveled surfaces with an accelerometer established inertial profiling reference...
-
R409.6 Gripping Surface
R409.6 Gripping Surface. Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides....
-
Loose Fill Surfaces
Loose Fill Surfaces. The predominant surface characteristic is one where many loose particles are combined to create the surface system. ...
-
11B-802.1.1 Floor or ground surface
The floor or ground surface of wheelchair spaces shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
5.4 Transfer Supports Recommendations
5.4 Transfer Supports Recommendations...
-
11B-902.1 General
Dining surfaces and work surfaces shall comply with Sections 11B-902.2 and 11B-902.3....
-
11B-902.1 General
Dining surfaces and work surfaces shall comply with Sections 11B-902.2 and 11B-902.3....
-
11B-302 FLOOR OR GROUND SURFACES
[See subsections ...]
-
Common Questions (Floor and Ground Surfaces)
Common Questions
-
11B-302 Floor or ground surfaces.
[See subsections ...]
-
11B-302 Floor or ground surfaces
[See subsections ...]
-
Performance for Surface Firmness and Stability
Performance for Surface Firmness and Stability In addition to the visual inspection and calculation of the surface deficiency score, the firmness and stability of the surfaces were measured...
-
Stability or Stable Surface
Stability or Stable Surface. ...
-
Clear Deck Space: ADA Standard Section 1009.4.1
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....