Q11: When will utility trench work require compliance with ADA curb ramp requirements?...
Search Results "Ramp Rise"
Commonly Searched Documents
- 
    
  
  Q11: Utility Trench Work and Curb Ramp Compliance
  
- 
    
  
  Slope [§405.2] and Cross Slope [§405.3]
  Slope [§405.2] and Cross Slope [§405.3] Slope represents the proportion of vertical rise to horizontal length and is specified in the Standards as a ratio (e.g., 1:12).... 
- 
    
  
  G. What are Detectable Warnings, Why are They Required, and Where Must They be Provided?
  The ADA Standards require that curb ramps include features called “detectable warnings.”... 
- 
    
  
  11B-705.1.2.2.2.1 One entrance/exit point
  Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and... 
- EZCurb Ramp - Vertical Barrier Removal Instructional Video
- 
    
  
  Sec.36.304(b)(1)
  (1) Installing ramps;... 
- 
    
  
  § 36.304(b)(1)
  (1) Installing ramps;... 
- 
    
  
  Boarding Pier Clearances: ADA Standard Section 1003.3.2
  These requirements do not establish a minimum length for accessible boarding piers at boat launch ramps.... 
- 
    
  
  Built-up Curb Ramps [4.7.6]
  Built-up curb ramps are permitted where they do not project into vehicular traffic lanes or access aisles at parking spaces and passenger loading zones.... 
- 
    
  
  4.7.4 Surface
  Surfaces of curb ramps shall comply with 4.5.... 
- 
    
  
  4.7.4 SURFACE
  Surfaces of curb ramps shall comply with 4.5.... 
- 
    
  
  11B-1003.3.2 Boarding pier clearances
  These requirements do not establish a minimum length for accessible boarding piers at boat launch ramps.... 
- 
    
  
  R304.2.1 Turning Space
  A turning space 1.2 m (4.0 ft) minimum by 1.2 m (4.0 ft) minimum shall be provided at the top of the curb ramp and shall be permitted to overlap other turning spaces and clear spaces.... 
- 
    
  
  R304.2.3 Flared Sides
  Where a pedestrian circulation path crosses the curb ramp, flared sides shall be sloped 10 percent maximum, measured parallel to the curb line. Advisory R304.2.3 Flared Sides.... 
- 
    
  
  R407.3 Cross Slope
  The cross slope of ramp runs shall be 2 percent maximum.... 
- 
    
  
  Access and Construction Database
  Access and Construction Database - The settlement shall include the implementation of sidewalk and curb ramp asset management system.... 
- 
    
  
  c-i
  If Yes, is a ramp or sloped hallway provided? Yes No If Yes, go to question E1-d.... 
- 
    
  
  A7
  Is the width of the curb ramp surface at least 36 inches (not counting the side flares)? [ADA Standards § 4.7.3] Yes No... 
- 
    
  
  B7-a
  Is the curb ramp surface at least 36 inches wide, excluding flared sides? [ADA Standards § 4.7.3] Yes No... 
- 
    
  
  e-i
  Is the curb ramp surface at least 36 inches wide, excluding flared sides? [ADA Standards § 4.7.3] Yes No... 
- 
    
  
  f-viii
  If the ramp or landing has a vertical drop-off on either side, is edge protection provided? [ADA Standards § 4.8.7] Yes No... 
- 
    
  
  11B-1008.2.5.3.2 Handrail height
  The top of handrail gripping surfaces shall be 20 inches (508 mm) minimum and 28 inches (711 mm) maximum above the ramp surface.... 
- 
    
  
  1008.2.5.3.2 Handrail Height
  The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface.... 
- 
    
  
  1008.2.5.3.2 Handrail Height
  The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface.... 
