Q11: When will utility trench work require compliance with ADA curb ramp requirements?...
Search Results "Ramp Rise"
Commonly Searched Documents
-
Q11: Utility Trench Work and Curb Ramp Compliance
-
Slope [§405.2] and Cross Slope [§405.3]
Slope [§405.2] and Cross Slope [§405.3] Slope represents the proportion of vertical rise to horizontal length and is specified in the Standards as a ratio (e.g., 1:12)....
-
G. What are Detectable Warnings, Why are They Required, and Where Must They be Provided?
The ADA Standards require that curb ramps include features called “detectable warnings.”...
-
11B-705.1.2.2.2.1 One entrance/exit point
Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and...
- EZCurb Ramp - Vertical Barrier Removal Instructional Video
-
Sec.36.304(b)(1)
(1) Installing ramps;...
-
§ 36.304(b)(1)
(1) Installing ramps;...
-
Boarding Pier Clearances: ADA Standard Section 1003.3.2
These requirements do not establish a minimum length for accessible boarding piers at boat launch ramps....
-
Built-up Curb Ramps [4.7.6]
Built-up curb ramps are permitted where they do not project into vehicular traffic lanes or access aisles at parking spaces and passenger loading zones....
-
4.7.4 Surface
Surfaces of curb ramps shall comply with 4.5....
-
4.7.4 SURFACE
Surfaces of curb ramps shall comply with 4.5....
-
11B-1003.3.2 Boarding pier clearances
These requirements do not establish a minimum length for accessible boarding piers at boat launch ramps....
-
R304.2.1 Turning Space
A turning space 1.2 m (4.0 ft) minimum by 1.2 m (4.0 ft) minimum shall be provided at the top of the curb ramp and shall be permitted to overlap other turning spaces and clear spaces....
-
R304.2.3 Flared Sides
Where a pedestrian circulation path crosses the curb ramp, flared sides shall be sloped 10 percent maximum, measured parallel to the curb line. Advisory R304.2.3 Flared Sides....
-
R407.3 Cross Slope
The cross slope of ramp runs shall be 2 percent maximum....
-
Access and Construction Database
Access and Construction Database - The settlement shall include the implementation of sidewalk and curb ramp asset management system....
-
c-i
If Yes, is a ramp or sloped hallway provided? Yes No If Yes, go to question E1-d....
-
A7
Is the width of the curb ramp surface at least 36 inches (not counting the side flares)? [ADA Standards § 4.7.3] Yes No...
-
B7-a
Is the curb ramp surface at least 36 inches wide, excluding flared sides? [ADA Standards § 4.7.3] Yes No...
-
e-i
Is the curb ramp surface at least 36 inches wide, excluding flared sides? [ADA Standards § 4.7.3] Yes No...
-
f-viii
If the ramp or landing has a vertical drop-off on either side, is edge protection provided? [ADA Standards § 4.8.7] Yes No...
-
11B-1008.2.5.3.2 Handrail height
The top of handrail gripping surfaces shall be 20 inches (508 mm) minimum and 28 inches (711 mm) maximum above the ramp surface....
-
1008.2.5.3.2 Handrail Height
The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....
-
1008.2.5.3.2 Handrail Height
The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....