Figure 604.8.1.4 Wheelchair Accessible Toilet Compartment Toe Clearance...
Search Results "Portable Toilet"
Commonly Searched Documents
-
604.8.1.4 Toe Clearance
-
4.1.6(3)(e)(iii)
(iii) When existing toilet or bathing facilities are being altered and are not made accessible, signage complying with 4.30.1, 4.30.2, 4.30.3, 4.30.5, and 4.30.7 shall be provided indicating...
-
604.8.1.4 Toe Clearance
[ECTCR UFAS 4.17.4] Figure 604.8.1.4 Wheelchair Accessible Toilet Compartment Toe Clearance...
-
604.8.1.4 Toe Clearance
Figure 604.8.1.4 Wheelchair Accessible Toilet Compartment Toe Clearance...
-
Entrances
Entrances Problem The entrance area must be level (no level change greater than ½ inch) and should not slope steeply in any one direction. All door openings must provide a...
-
M302.4.2 Clearance Around Base
The base of the diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of...
-
M302.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...
-
5.3.6 Entrance
The entrance to the toilet shall be level with the surrounding surface....
-
11B-809.10.7.5 Controls
Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum.
-
EZ-ACCESS Suitcase Singlefold Ramp Video
Requires the Registered User plan or above. Login!
-
604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
11B-604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
11B-604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
Alterations and water closet clearances in single-user toilet rooms with in-swinging doors. (Section-by-Section Analysis)
Alterations and water closet clearances in single-user toilet rooms with in-swinging doors....
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
5.3.2.1 Size
The clear floor or ground space shall be 60 inches (1525 mm) wide minimum measured parallel with the back of the pit toilet, and 56 inches (1420 mm) deep minimum measured parallel to the...
-
11B-604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
Doors
Doors: a. Main Lobby restroom: provide a restroom vestibule door with at least 18" of maneuvering clearance on the latch side of the door. See Standards § 4.13.6.
-
§ 35.151(b)(4)(ii)(B)
(B) For the purposes of this section, the term path of travel also includes the restrooms, telephones, and drinking fountains serving the altered area.