Signage shall comply with Chapter 11A, Section 1143A and Chapter 11B, Section 11B-703.5 as applicable, requirements for visual characters and include the International Symbol of Accessibility...
Search Results "Numeric Character"
Commonly Searched Documents
-
1009.9 Signage
-
Inputs
We also asked about alphabetic and numeric keypad arrangements and whether the specified function keys and identification symbols were sufficient for the types of operations typically performed...
-
11B-703.8.8 Line spacing
Low resolution VMS characters shall comply with Section 11B-703.5.9....
-
11B-703.8.10 Finish
The background of low resolution VMS characters shall have a non-glare finish....
-
11B-703.8.10 Finish
The background of low resolution VMS characters shall have a non-glare finish....
-
11B-703.8.8 Line spacing
Low resolution VMS characters shall comply with Section 11B-703.5.9....
-
11B-411.2.1.2.1 Keypads
Characters and symbols shall be centered on the corresponding button. The number five key shall have a single raised dot....
-
703.3.2 Position
Braille shall be separated 3/8 inch (9.5 mm) minimum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements....
-
703.3.2 Position
Braille shall be separated 3/8 inch (9.5 mm) minimum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements. ...
-
D. Signage
Existing tactile signage will be relocated to between 48 inches measured to the baseline of the lowest tactile character and 60 inches measured to the baseline of the highest tactile character...
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
T702.5 Stroke Thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
Q7: Curb Ramp for a Sidewalk that is Not Made of Concrete or Asphalt
A "prepared surface for pedestrian use" can be constructed out of numerous materials, including concrete, asphalt, compacted soil, decomposed granite, and other materials. ...
-
Exemptions for an Entire Trail or Beach Access Route [1017.1, Exception 2 and 1018.1, Exception 2]
When extreme or numerous conditions for exceptions make it impractical to construct a trail or beach access route that complies with the technical requirements, the ABA Standards provide...
-
11B-406 Curb ramps, blended transitions and islands
[2010 ADAS] 406 Curb Ramps ETA Editor's Note The differences between 2010 ADAS Section 406 and CBC Section 11B-406 are numerous, as indicated by the italicized text, which is used...
-
11B-407.4.8.1.3 Floor arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate. Exception: Reserved....
-
M1
.), is a sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door and centered 60 inches above the floor?...
-
11B-411.2.1.7.2 Assignment by touch screen hall call console
The display screen shall indicate the elevator assignment characters and a verbal announcement shall be made of the assigned elevator responding to the call....
-
703.6.1 Pictogram Field
Characters and braille shall not be located in the pictogram field....
-
R410.7 Height from Finish Surface
Visual characters shall be 1.0 m (3.25 ft) minimum above the finish surface....
-
§8.3 Substantial impairment
Substantial impairment means a significant loss of the integrity of finished materials, design quality, or special character resulting from a permanent alteration....
-
703.6.1 Pictogram Field
Characters and braille shall not be located in the pictogram field....