An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
Search Results "Non-Occupiable Space"
Commonly Searched Documents
-
11B-403.5.3 Passing spaces
-
11B-403.5.3 Passing spaces
An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
-
4.2.3* Wheelchair Turning Space
The space required for a wheelchair to make a 180-degree turn is a clear space of 60 in (1525 mm) diameter (see Fig. 3(a)) or a T-shaped space (see Fig. 3(b))....
-
4.2.3* WHEELCHAIR TURNING SPACE
The space required for a wheelchair to make a 180-degree turn is a clear space of 60 in (1525 mm) diameter (see Fig. 3(a)) or a T-shaped space (see Fig. 3(b))....
-
Clear Floor Space [4.27.2]
Clear Floor Space [4.27.2] Clear floor space for a forward or side approach is required at controls, dispensers, receptacles, and other operable equipment as specified in 4.2; those recessed...
-
1009.7.1 Size
Each exterior area for assisted rescue shall be sized to accommodate wheelchair spaces in accordance with Section 1009.6.3....
-
Clear Floor Space [§309.2]
Clear Floor Space [§309.2] Clear floor space can be oriented for a side approach instead of a forward approach at most operable parts....
-
M. Turning Space
M. Is there an area in each public restroom in which a person who uses a wheelchair can turn around - either a 60" diameter circle or a "T"-shaped turn area as shown in Figure 3...
-
A4.2.3 Wheelchair Turning Space
These guidelines specify a minimum space of 60 in (1525 mm) diameter or a 60 in by 60 in (1525 mm by 1525 mm) T-shaped space for a pivoting 180-degree turn of a wheelchair....
-
Vanity Counter Top Space: ADA Standard Section 806.2.4.1
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
Clear Floor Space [4.18.3]
Clear Floor Space [4.18.3] Clear floor space at least 30 inches wide is required, including between partitions where they are provided (when shields do not extend beyond the front of...
-
4.35.2 Clear Floor Space
A clear floor space allowing a person using a wheelchair to make a 180-degree turn shall be provided in every accessible dressing room entered through a swinging or sliding door....
-
11B-809.10.4 Sufficient maneuvering space
The clear maneuvering space shall be permitted to include knee and toe clearance under bathroom fixtures....
-
4.3.4 Passing Space
If an accessible route has less than 60 in (1525 mm) clear width, then passing spaces at least 60 in by 60 in (1525 mm by 1525 mm) shall be located at reasonable intervals not to exceed...
-
4.3.4 PASSING SPACE
If an accessible route has less than 60 in (1525 mm) clear width, then passing spaces at least 60 in by 60 in (1525 mm by 1525 mm) shall be located at reasonable intervals not to exceed...
-
A4.2.3 WHEELCHAIR TURNING SPACE
This standard specifies a minimum space of 60 in (1525 mm) diameter for a pivoting 180-degree turn of a wheelchair....
-
T101.1 Purpose
These Non-Rail Vehicle Guidelines, which consist of Chapters 1 through 7, contain scoping and technical requirements for new, used or remanufactured non-rail vehicles to ensure their accessibility...
-
605.3 Clear Floor Space
605.3 Clear Floor Space. A clear floor or ground space complying with 305 positioned for forward approach shall be provided....
-
Error/Omission: The door to the toilet room swings into the required clear floor space at accessible fixtures, controls, and dispensers.
For example, if a person using a wheelchair is positioned in the clear floor space at the paper towel dispenser and that clear floor space overlaps the space needed to swing the door open...
-
Inside Dimensions of Elevator Cars: ADA Standard Section 409.4.1
Section 409.4.1 covers the current ADA Standards for the inside dimensions of private residence elevator cars.
-
11B-804.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap....
-
11B-804.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap....
-
11B-804.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap....
-
11B-409.4.1 Inside dimensions of elevator cars
Elevator cars shall provide a clear floor space of 36 inches (914 mm) minimum by 48 inches (1219 mm) minimum and shall comply with Section 11B-305....